Atlas Copco Stationary Air Compressors Manuale Utente
Instruction book
2920 1521 00
31
Period
Running
hours
hours
Service
Plan
Plan
See
section
section
See
notes
below
table
notes
below
table
Operation
Daily
-- -- 3.4
--
Drain
condensate
"
--
--
--
--
On SF Full-Feature, check dewpoint
Monthly
250
--
5.1
1
Inspect air filter
3-monthly 500
-- -- --
Check
pressure
drop
over Atlas Copco filters
(optional)
6-monthly -- -- 5.4
--
Operate
safety
valve
"
-- -- -- --
Clean
compressor
"
--
--
--
--
On SF Full-Feature, brush or blow off the finned
surface of the condenser
surface of the condenser
"
--
--
--
--
On SF Full-Feature, clean condensate trap
internally
internally
Yearly
-- -- 5.4
--
Test
safety
valve
"
-- -- -- --
Have
electrical
components/shut-down
switch
tested
"
2500
I
5.2
--
Check tension/condition of V-belt(s)
"
5000
A
5.1
--
Replace air filter
"
5000
A
--
2
Have ball valve mechanism of condensate trap
inspected
inspected
"
5000
A
5.2 -- Replace
V-belt(s)
2-yearly
5000
B
--
2
Have orbiting scroll bearing greased
"
10000
B
--
2
Clean compressor element fan and duct. Clean
compressor element fins, have seals replaced
compressor element fins, have seals replaced
"
10000
B
--
2
Have pin crank bearings greased
Notes:
1.
Check more frequently if operating in a dusty atmosphere. Check for cleanness and damage.
Replace a dirty or damaged filter by a new one.
Replace a dirty or damaged filter by a new one.
2.
Consult Atlas Copco.