Atlas Copco Stationary Air Compressors User Manual

Page of 70
Instruction book 
2920 1521 00 
36 
 
7.3 Overload relays for SF1-8 
 
Frequency Voltage 
SF1 
single-
phase 
SF2 
single-
phase 
SF2  
3-phase 
SF4  
3-phase 
SF6  
3-phase 
SF8  
3-phase 
 
 
 
 
 
 
 
 
IEC 
 
 
 
 
 
 
 
50 Hz 
230 V 
12 A 
14.5 A 
8.3 A 
14 A 
8.3 and 14 A 
2x 14 A 
50 Hz 
400 V 
 
 
4.8 A 
8.2 A 
4.8 and 8.2 A 
2x 8.2 A 
60 Hz 
380 V 
 
 
5.1 A 
8.5 A 
5.1 and 8.5 A 
2x 8.5 A 
50 Hz 
500 V 
 
 
3.8 A 
6.5 A 
3.8 and 6.5 A 
2x 6.5 A 
 
 
 
 
 
 
 
 
CSA/UL 
 
 
 
 
 
 
 
60 Hz 
230 V 
10.2 A 
14.7 A 
9.2 A 
15.3 A 
9.2 and 15.3 A  2x 15.3 A 
60 Hz 
440/460 V 
 
 
4.6 A 
7.7 A 
4.6 and 7.7 A 
2x 7.7 A 
 
Note: SF6 Twin have compressor modules of a different size, the first value is valid for the smaller 
SF2 module and the second one is valid for the bigger SF4 module 
 
 
7.4 Overload relays for SF6-15 Multi 
 
Frequency Voltage 
SF6 
 
3-phase 
SF8  
3-phase 
SF11  
3-phase 
SF15  
3-phase 
 
 
 
 
 
 
IEC 
 
 
 
 
 
50 Hz 
230 V 
8 and 14 A 
2x 14 A 
3x 14 A 
4x 14 A 
50 Hz 
400 V 
4.8 and 8 A 
2x 8 A 
3x 8 A 
4x 8 A 
60 Hz 
380 V 
5 and 8.5 A 
2x 8.5 A 
3x 8.5 A 
4x 8.5 A 
50 Hz 
500 V 
3.6 and 6.4 A  2x 6.4 A 
3x 6.4 A 
4x 6.4 A 
 
 
 
 
 
 
CSA/UL 
 
 
 
 
 
60 Hz 
230 V 
9 and 15 A 
2x 15 A 
3x 15 A 
4x 15 A 
60 Hz 
440/460 V 
4.5 and 7.5 A  2x 7.5 A 
3x 7.5 A 
4x 7.5 A 
60 Hz 
575 V 
3.5 and 5.5 A  2x 5.5 A 
3x 5.5 A 
4x 5.5 A 
 
Note: SF6 have compressor modules of a different size, the first value is valid for the smaller SF2 
module (lower element) and the second one is valid for the bigger SF4 module (higher element)