Atlas Copco Stationary Air Compressors User Manual

Page of 70
Instruction book 
2920 1521 00 
47 
8.3.4 A service warning message exists 
 
1.  LED (7) is alight and the main screen will change into a screen similar to that shown in Fig. 8.9. 
 
Compressor Outlet 
 
7.0 bar 
 
 
 
** Service 
Required 
 
**
↓ 
Menu 
***
*** 
- - - - 
F1 F2 F3 
 
Fig. 8.9 Example of a service warning screen 
 
 
2.  The indicators (***) are blinking and the service warning message appears alternately with the 
messages indicating whether the compressor is in operation or not (Compressor Running or 
Compressor Off). 
3.  Press the key "Menu" (F1) and the tabulator key (5) to select the Status data menu: the option 
"Service" is blinking. 
4.  Scroll to this option and select it by pressing the tabulator key (5), two options may blink: 
 
"Inputs": option is not applicable. 
 
"Plan": if a service plan interval is exceeded.  See section 8.15.2. 
5.  Stop the compressor and switch off the voltage. 
6.  The service message was referring to "Plan": carry out the service actions related to the indicated 
plans.  Reset the timers of the related plans as described in section 8.13. 
 
 
8.4 Measured data menu 
 
Function 
 
To call up information regarding the actually measured data and the status of some inputs such as the 
motor overload protection per compressor module. 
 
Procedure 
 
1.  Starting from the Main screen (see section 8.1.2): 
press the key "Menu" (F1) 
- press 
the 
↓ key until the option "Measured data" is followed by a horizontal arrow 
press the tabulator key (5) to activate the menu 
 
Compressor Outlet 
 
7.0 bar 
┤ 
Element 1 
 
75 °C 
Element 2 
 
70 °C 
↓ 
Menu  
Extra 
F1 F2 F3 
 
Fig. 8.10 Example of a measured data screen