Boot Mode Commands
191
6-00020-02
SNC 5100
Boot Mode Commands
diagBoot
This command is used only to transition an SNC 5100 from normal operations 
to the special diagnostic mode. 
Caution
All SCSI and FC cables must be disconnected before entering the 
diagBoot
 command.
• The 
diagBoot 
command first ensures that the
 /nvfs:mt 
directory 
exists. 
• It copies the existing bootline to a file in the 
/nvfs:mt 
directory on the 
SNC 5100.
• It installs a new bootline directing the SNC 5100 to boot using a special 
diagnostic startup 
script /ffs:mt/diagnstk.rc.
 
• It renames the persistent map file 
config/device.map
 as 
config/device.bak 
(a new file will be generated after rebooting).
• It issues a 
reboot
 command to put the changes into effect.
normalBoot
The 
normalBoot
 command is used only to transition the SNC 5100 from the 
special diagnostic mode to resume normal operation. 
• It restores the bootline that was copied by 
diagBoot
• It erases the new persistent device map and renames the original map file 
config/device.map 
– restoring it for use when the SNC 5100 reboots.
• It reboots the SNC 5100.
Diagnostic Commands
This section is a reference for the commands that are available when the SNC 
5100 is booted in diagmode.
The command set is limited while in 
diagmode
. You will need to use the 
showBox
 command and three commands (with the suffix 
Test
) when testing 