Desa Motion Sensing Halogen Fixture 5525 User Manual

Page of 8
© 2007 DESA Specialty Products™ 
598-1311-00
1 Halogen 
Lamp
Sensor
Light Control
Requirements
•  The Light Control requires 120-volts AC.
•  If you want to use Manual Mode, the control must be 
wired through a switch.
•  Some codes require installation by a qualifi ed 
electrician.
•  This product is intended for use with the enclosed 
gasket and with a junction box marked for use in wet 
locations.
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off. 
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
Motion Sensing
Halogen Fixture
Model 5525
3 Wire 
Connectors
6 Screws
(3 sizes included)
Gasket
Mounting Bolt
Mounting Strap
OPERATION
* resets to Auto Mode at dawn.
MANUAL MODE
ON-TIME
10 5 1 TEST
10 5 1 TEST
ON-TIME
TEST
AUTO
Move ON-TIME Switch to 
1, 5, or 10 minutes
Mode Switch Summary 
Flip light switch 
off for one second 
then back on*
MANUAL MODE
AUTO
TEST
*  If you get confused while switching modes, turn the 
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
Note: When fi rst turned on wait about 1 
1
/
2
 minutes for 
the circuitry to calibrate.
Light Shield
Plastic Hanger
Rubber Plug
Put the ON-TIME switch on the bottom 
of the sensor in the TEST position.
Put the ON-TIME switch in the 1, 5, 
or 10 minute position.
Manual mode only works at night 
because daylight returns the sen-
sor to AUTO.
Flip the light switch off for one sec-
ond then back on to toggle between 
AUTO and MANUAL MODE.
Manual mode works only with the 
ON-TIME switch in the 1, 5, or 10 
position.
This package includes:
Mode:
On-Time
Works:
Day Night
Test
5 Seconds
x
x
Auto
1, 5, or 10 Min
x
Manual
Until Dawn*
x
... back on.
1 Second OFF 
then...
®