598-1311-00
TEST AND ADJUSTMENT
❒  Turn on the circuit breaker and light switch.
Avoid aiming the control at:
•  Objects that change temperature rapidly, such as 
heating vents and air conditioners. These heat 
sources could cause false triggering.
•  Areas where pets or traffi c may trigger the control.
•  Nearby large, light-colored objects refl ecting light 
may trigger the shut-off feature. Do not point other 
lights at the sensor.
NOTE:  Sensor has about 1 
1
/
2
 minutes warm up period 
before it will detect motion. When fi rst turned 
on, wait about 1 
1
/
2
 minutes.
RANGE
10 5 1 TEST
ON-TIME
Bottom of Sensor
MIN MAX
 Maximum 
Range  Maximum
  
Coverage 
Angle
70 ft. 
(21 m)
8 ft. 
(2.4 m)
 
Least Sensitive 
Most Sensitive
The detector is most sensitive to motion across its fi eld 
of view.
❒  Loosen the clamp screw in the 
sensor ball joint and gently 
rotate the sensor.
❒  Walk through the coverage area 
noting where you are when the 
lights turn on (also, the LED will 
fl ash several times when motion 
is detected). Move the sensor 
head up, down, or sideways to 
change the coverage area. Keep 
the sensor at least 1" (2.5 
cm) away from the lamp.
❒  Adjust the RANGE as needed. 
RANGE set too high may 
increase false triggering.
❒  Secure the sensor head by 
tightening the clamp screw. 
Do not overtighten the screw.
❒  Set the amount of TIME you 
want the lights to stay on after motion is detected 
(1, 5, or 10 minutes).
SPECIFICATIONS
Range  . . . . . . . . . . . . .  Up to 70 ft. (21 m) [varies with 
surrounding temperature].
Sensing Angle . . . . . . .  Up to 180°
Electrical Load . . . . . . .  Up  to  250  Watts  Maximum 
Incandescent.
Power Requirements . .  120 VAC, 60 Hz
Operating Modes . . . . .  TEST,  AUTO  and  MANUAL 
MODE
Time Delay  . . . . . . . . .  1, 5, 10 minutes
Replacement lamp . . . . T3, 250W (or less) halogen 
120 VAC
DESA Specialty Products reserves the right to dis-
continue products and to change specifi cations at any 
time without incurring any obligation to incorporate new 
features in products previously sold.
180°
Motion
Motion
Sensor
❒  Turn the RANGE control to the mid position and 
the ON-TIME control to the TEST position.
Clamp 
Screw
Ball 
Joint
Aim Sensor 
Down for Short 
Coverage
Aim Sensor 
Higher for Long 
Coverage