Delta Tau GEO BRICK DRIVE User Manual

Page of 294
 Geo Brick Drive User Manual 
Specifications 
 19 
 
8-Axis Geo Brick Drive 
GBL8-xx-552  GBL8-xx-882  GBL8-xx-582  GBL8-xx-852 
Axes 
1-4 
5-8  
1-4  
5-8 
1-4 
5-8 
1-4 
5-8 
Output Continuous Current (rms/axis) 
5A 
5A 
8A 
8A 
5A 
8A 
8A 
5A 
Output Peak Current for 2 sec (rms/axis) 
10A 
10A 
16A 
16A 
10A 
16A 
16A 
10A 
Max ADC (I
2
T Settings) 
16.26A 
16.26A 
26.02A 
26.02A 
16.02A 
26.02A 
26.02A 
16.02A 
Rated Input Current @240 3-phase(all axes) 
26A 
42A 
34A 
34A 
Output Power Per Axis  
(Modulation depth 60% RMS) 
1247W 
1995W 
1247W 
1995W 
1995W 
1247W 
Output Power Total 
9976W 
15960W 
12968W 
12968W 
Power Dissipation  
998W 
1596W 
1297W 
1297W 
PWM Frequency Operating Range [KHz] 
1 – 18 
AC Input Line Voltage [VAC] 
110
-20% 
– 240
+10%
 (~87 -- 264) 
DC Input Line Voltage [VDC]- DC operation 
12VDC to 340VDC 
Logic Power 
24VDC ±5%, 4A 
Continuous Shunt Power [Watts] 
5000W 
Peak Shunt Power rating [Watts] 
10000W 
Recommended Shunt Resistor [Ohms] 
GAR 15 (15 Ω) 
Recommended Shunt Power Rating [Watts] 
300W 
 
 
Note 
Electrical  specifications  are  specified  for  three-phase  AC  bus  power. 
De-rating applies in single-phase AC, or DC Operation.