Delta Tau GEO BRICK DRIVE User Manual
Geo Brick Drive User Manual
Specifications
19
8-Axis Geo Brick Drive
GBL8-xx-552 GBL8-xx-882 GBL8-xx-582 GBL8-xx-852
Axes
1-4
5-8
1-4
5-8
1-4
5-8
1-4
5-8
Output Continuous Current (rms/axis)
5A
5A
8A
8A
5A
8A
8A
5A
Output Peak Current for 2 sec (rms/axis)
10A
10A
16A
16A
10A
16A
16A
10A
Max ADC (I
2
T Settings)
16.26A
16.26A
26.02A
26.02A
16.02A
26.02A
26.02A
16.02A
Rated Input Current @240 3-phase(all axes)
26A
42A
34A
34A
Output Power Per Axis
(Modulation depth 60% RMS)
1247W
1995W
1247W
1995W
1995W
1247W
Output Power Total
9976W
15960W
12968W
12968W
Power Dissipation
998W
1596W
1297W
1297W
PWM Frequency Operating Range [KHz]
1 – 18
AC Input Line Voltage [VAC]
110
-20%
– 240
+10%
(~87 -- 264)
DC Input Line Voltage [VDC]- DC operation
12VDC to 340VDC
Logic Power
24VDC ±5%, 4A
Continuous Shunt Power [Watts]
5000W
Peak Shunt Power rating [Watts]
10000W
Recommended Shunt Resistor [Ohms]
GAR 15 (15 Ω)
Recommended Shunt Power Rating [Watts]
300W
Note
Electrical specifications are specified for three-phase AC bus power.
De-rating applies in single-phase AC, or DC Operation.
De-rating applies in single-phase AC, or DC Operation.