Delta Tau GEO BRICK LV Reference Manual

Page of 760
Turbo PMAC/PMAC2 Software Reference
 
Turbo PMAC Global I-Variables 
 155 
Bit 23 of Ixx95 specifies whether the position is interpreted as an unsigned or a signed value.  If the bit is 
set to 0, it is interpreted as an unsigned value, if the bit is 1, it is interpreted as a signed value.  Because 
Acc-28A produces signed values, Ixx95 should be set to $B10000 when using Acc-28A.  Acc-28B 
produces unsigned values, so Ixx95 should be set to $310000 when using Acc-28B. 
Sanyo Absolute Encoder Read:  If Ixx95 is set to $320000 or $B20000, Motor xx will expect its power-
on position from the Acc-49 Sanyo Absolute Encoder converter board at the Turbo PMAC address 
specified by Ixx10. 
The first hex digit of Ixx95, which can take a value of 3 or B in this mode, specifies whether the position 
is interpreted as an unsigned value (first digit = 0) or as a signed value (first digit = 8).  Set Ixx95 to 
$320000 for unsigned, or to $B20000 for signed. 
Yaskawa Absolute Encoder Read:  If Ixx95 is set to $710000 or $F10000, Motor xx will expect its 
power-on position from the Yaskawa Absolute Encoder converter board at the multiplexer port address 
specified by Ixx10. 
The first hex digit of Ixx95, which can take a value of 7 or F in this mode, specifies whether the position 
is interpreted as an unsigned value (first digit = 0) or as a signed value (first digit = 8).  Set Ixx95 to 
$710000 for unsigned, or to $F10000 for signed. 
In this mode, Ixx99 specifies the number of bits per revolution for a single turn of the Yaskawa absolute 
encoder.  It must be set greater than 0 to use the multi-turn absolute capability of this encoder. 
MACRO Station Yaskawa Absolute Encoder Read:  If Ixx95 is set to $720000 or $F20000, Motor xx 
will expect its power-on position from a Yaskawa Absolute Encoder through a MACRO Station.  In this 
mode, Ixx10 specifies the MACRO node number at which the position value will be read by Turbo 
PMAC itself.  Set-up variable MI11x for the MACRO Station tells the Station how to read the Yaskawa 
Encoder converter connected to its own multiplexer port or serial port. 
The first hex digit of Ixx95, which can take a value of 7 or F in this mode, specifies whether the position 
is interpreted as an unsigned value (first digit = 0) or as a signed value (first digit = 8).  Set Ixx95 to 
$720000 for unsigned, or to $F20000 for signed. 
In this mode, Ixx99 specifies the number of bits per revolution for a single turn of the Yaskawa absolute 
encoder.  It must be set greater than 0 to use the multi-turn absolute capability of this encoder. 
MACRO Station R/D Converter Read:  If Ixx95 is set to $730000 or $F30000, Motor xx will expect its 
power-on position from an R/D converter through a MACRO Station or compatible device.  In this mode, 
Ixx10 specifies the MACRO node number at which Turbo PMAC will read the position value itself.  Set-
up variable MI11x for the matching node on the MACRO Station tells the Station how to read the R/D 
converter connected to its own multiplexer port. 
The first hex digit of Ixx95, which can take a value of 7 or F in this mode, specifies whether the position 
is interpreted as an unsigned value (first digit = 0) or as a signed value (first digit = 8).  Set Ixx95 to 
$730000 for unsigned, or to $F30000 for signed. 
If Ixx99 is set greater than 0, the next higher numbered R/D converter at the same multiplexer port 
address is also read and treated as a geared-down resolver, with Ixx99 specifying the gear ratio.  Ixx98 is 
also set greater than 0, the following R/D converter at the same multiplexer port address is read and 
treated as a third resolver geared down from the second, with Ixx98 specifying that gear ratio. 
MACRO Station Parallel Data Read: If Ixx95 is set to $740000 or $F40000, Motor xx will expect its 
power-on position from a parallel data source through a MACRO Station or compatible device.  In this 
mode, Ixx10 specifies the MACRO node number at which Turbo PMAC will read the position value 
itself.  Set-up variable MI11x for the matching node on the MACRO Station tells the Station how to read 
the parallel data source connected to it. 
The first hex digit of Ixx95, which can take a value of 7 or F in this mode, specifies whether the position 
is interpreted as an unsigned value (first digit = 0) or as a signed value (first digit = 8).  Set Ixx95 to 
$740000 for unsigned, or to $F40000 for signed.