Bosch Appliances Webcam 3922 988 43318 User Manual

Page of 172
  2
Bosch Security Systems | 04-2003 | 3922 988 43318 en
Digital Congress Network | Installation  and Operating Manual | Chapter 5 - Control using PC
en | 5-8
Connection PC to CCU
FIG 5-7   Multi-CCU System with control PC and Camera control
1
2
3
4
5
6
7
8
9
DCD
RD
TD
DTR
GND
DSR
RTS
CTS
RI
1
2
3
4
5
6
7
8
9
DCD
RD
TD
DTR
GND
DSR
RTS
CTS
RI
RS232
RS232
1
2
3
4
5
6
7
8
9
DCD
RD
TD
DTR
GND
DSR
RTS
CTS
RI
1
2
3
4
5
6
7
8
9
DCD
RD
TD
DTR
GND
DSR
RTS
CTS
RI
Mult-CCU
Trunk
115V-T4A  230V -T2A
Port 1
Port 2
Rec.
Line
In
Out
In
Out
Symmetrical
I n
Out
Master CCU PC
RS232
RS232
Control PC
OS/2 PC
EXAMPLE 2:  Multi-CCU System with control PC and Camera control
Control PC requirements:
- Windows 95, 98, NT 4.0 or 2000
- Start-up software LBB 3590.
- DCN software application modules as 
required.
Master CCU PC requirements:
- OS/2 version 3.0 Warp or higher
- Multi-CCU software LBB 3586
- UPS (Uninterrupted Power Supply) 
recommended
Female
Female
‘Null modem ’
Video switcher (if applicable)
OUT
To next Multi-CCU
LBB 3500/35
Control PC
COM 1
COM 2
COM 1
COM 2
LBB 3511/00
Multi-CCU
PC-card
‘DIRECT’  DCN PC control
  - Master CCU Port 1 
- Protocol:  FULL 
- Baudrate: 115.2k
IMPORTANT: The LBB 3510/00 PC Network 
card CANNOT be used in a PC running 
Windows NT 4.0 or 2000. 
Simultaneous use of the PC-Network card and 
‘DIRECT’  connection is NOT possible.
NOTES:  
1. When using the ‘DIRECT’  method the 
functions of the PC-Network card are NOT 
available (i.e. headphones and intercom). 
These functions are available on the DCN 
Concentus units or with the ‘Multi-purpose 
connection unit’ LBB 3540/15.
2. The baud-rate setting of the Master CCU 
PC port and the corresponding Control PC 
port must be the same. The available baud 
rate settings are 9600, 19200, 38400, 57600 
and 115200. Baud rate setting on the Master 
CCU PC must be set in the 
CCU_CFG
 file 
(SERIAL SPEED I <baud-rate>). For more 
information refer to the README.TXT file 
of the Multi CCU software LBB 3586. Baud-
rate setting on the DCN Control PC must 
be set in the 
DCN.INI
 file. This file can be 
found in the WINDOWS or WINNT 
directory.
[Server]
SerialLink=Yes
[Serial Link]
ComPort=1
Baudrate=<Baudrate>
FullProtocol=Yes
Mult-CCU
Trunk
115V-T4A  230V -T2A
Port 1
Port 2
Rec.
Line
In
Out
In
Out
Symmetrical
I n
Out
IN
From Multi-CCU
1
n (max.16)
9-pole D-type cable connections
75 Ohm Coax cable
Male
Male
LTC 8506/00 
e.g. Card encoder or
The COM-port for Master CCU control is 
selected during software installation. 
Select COM 1. 
By default an ID-chip card encoder is connected 
to COM 2.  COM 2 settings can be changed in 
the dcn.ini file (see Table 5-11).
      serial printer etc.
Power
Code Out
Alarm
Status
Battery Low
ALLEGIANT
Video System
LBB 3500/35
Male
Male
For COM-port settings of the Master CCU PC
(see 
See 
for installation details