Bosch Appliances Security Camera NBC-265-W User Manual

Page of 101
112 en | Advanced Mode
IP Camera 200 Series
AR18-10-B012 | v1.54 | 2011.08
Installation and Operation Manual
Bosch Security Systems
deactivates all unencrypted connections allowing connections 
on the HTTPS port only.
RCP+ port 1756
Activating RCP+ port 1756 allows unencrypted connections on 
this port. To allow only encrypted connections, set the Off 
option to deactivate the port.
Telnet support
Activating Telenet support allows unencrypted connections on 
this port. To allow only encrypted connections, set the Off 
option to deactivate telnet support, making telnet connections 
impossible.
Interface mode ETH
If necessary, select the Ethernet link type for interface ETH
Depending on the device connected, it may be necessary to 
select a special operation type.
Network MSS [Byte]
Set the maximum segment size for the IP packet's user data 
here. This gives the option to adjust the size of the data packets 
to the network environment and to optimize data transmission. 
Please comply with the MTU value of 1,514 bytes in UDP mode.
iSCSI MSS [Byte]
Specify a higher MSS value for a connection to the iSCSI 
system than for the other data traffic via the network. The 
potential value depends on the network structure. A higher 
value is only useful if the iSCSI system is located in the same 
subnet as the camera.
Enable DynDNS
DynDNS.org is a DNS hosting service that stores IP addresses in 
a database ready for use. It allows selecting the device via the 
Internet using a host name, without having to know the current 
IP address of the device. Enable this service here. To do this, 
obtain an account with DynDNS.org and register the required 
host name for the device on that site.