Bosch Appliances Network Router D6100 User Manual
Conettix D6600/D6100 | Computer Interface Manual | 3.0
Computer Communication Protocols
12
Bosch Security Systems, Inc. | 1/07 | 4998122703-01
3.1.6
ADT SIA (Message Type S)
D6500 Byte Description
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
h S r r l [ # a a a a | d a m m - d d - y
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
ADT SIA
Example
Example
y t I h h : m m : s s E M M Z Z Z Z / **
*
t
Table 8:
ADT SIA (Message Type S) Byte Description
# Title
Description
1
Header Character (h) Optional. Check with the computer automation software for compatibility.
2
Message Type
S
3-4
Receiver Number
Receiver gateway number from 01 to 99.
5 Line/Group
Number
Line number in the receiver gateway that sent the message.
6
space
One space.
7 #
#
8-11
Account Number
Up to sixteen digits in the account number.
12 |
Separator. Indicates more data positions after account number.
13-32
Date and Time
Date and time.
33 E
SIA block code.
34-35
Event Code
SIA event code (refer to Appendix G ADT SIA Report Codes on page 149).
36-39
Zone
Zone number.
40
/
Separator.
41 ***
Next block of data.
42
Trailer Character
Typically, this is HEX 14.
3.1.7
Caller ID (Message Type e)
D6500 Byte Description
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22
Caller ID
Example
Example
h e r r 1 T T T T T T T T T T T T T T T T t
Table 9:
Caller ID (Message Type e) Byte Description
# Title
Description
1
Header Character (
h
)
Optional. Check with the computer automation software for compatibility.
2 Message
Type
e
3-4
Receiver Number
Receiver gateway Number from 01 to 99.
5 Line/Group
Number
Line number in the receiver gateway that sent the message.
6-21
Caller ID
Up to sixteen digits, Caller ID with less than sixteen characters is right aligned with
leading ASCII spaces.
leading ASCII spaces.
22 Trailer
Character
Typically, this is HEX 14.