Bosch Appliances Network Router D6100 User Manual

Page of 168
Conettix D6600/D6100 | Computer Interface Manual | 3.0  
Computer Communication Protocols 
 
 
12 
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 
 
3.1.6 
ADT SIA (Message Type S) 
D6500 Byte Description 
10 
11 
12 
13 
14 
15 
16 
17 
18 
19 
20 
21 
h S r r l [ # a a a a | d a m m - d d - y 
22 
23 
24 
25 
26 
27 
28 
29 
30 
31 
32 
33 
34 
35 
36 
37 
38 
39 
40 
41 
42 
ADT SIA 
Example 
y t I h h : m m : s s E M M Z Z Z Z / **
 
Table 8: 
ADT SIA (Message Type S) Byte Description 
 
# Title 
Description 
Header Character (h)     Optional. Check with the computer automation software for compatibility. 
Message Type    
3-4 
Receiver Number    
Receiver gateway number from 01 to 99.  
5 Line/Group 
Number 
Line number in the receiver gateway that sent the message. 
space 
One space.  
7 # 
#  
8-11 
Account Number 
Up to sixteen digits in the account number. 
12 | 
Separator. Indicates more data positions after account number. 
13-32 
Date and Time 
Date and time. 
33 E 
SIA block code.  
34-35 
Event Code 
SIA event code  (refer to Appendix G ADT SIA Report Codes on page 149). 
36-39 
Zone 
Zone number.  
40 
Separator.  
41 *** 
Next block of data.  
42 
Trailer Character 
Typically, this is HEX 14.  
 
3.1.7 
Caller ID (Message Type e) 
D6500 Byte Description 
10  11  12  13  14  15  16  17  18  19  20  21  22 
Caller ID 
Example 
h e r r 1 T T T T T T T T T T T T T T T T t 
 
Table 9: 
Caller ID (Message Type e) Byte Description 
 
# Title 
Description 
Header Character (
h
Optional. Check with the computer automation software for compatibility. 
2 Message 
Type 
3-4 
Receiver Number 
Receiver gateway Number from 01 to 99.  
5 Line/Group 
Number 
Line number in the receiver gateway that sent the message.  
6-21 
Caller ID 
Up to sixteen digits, Caller ID with less than sixteen characters is right aligned with 
leading ASCII spaces. 
22 Trailer 
Character 
Typically, this is HEX 14.