Bosch Appliances Network Router D6100 User Manual

Page of 168
Conettix D6600/D6100 | Computer Interface Manual | 3.0  
Computer Communication Protocols 
 
 
10 
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 
 
3.1.2 
Ademco 4-1 Express (Message Type b) 
D6500 Byte Description 
10  11  12  13  14  15  16  17  18  19  20  21 
22 
4-1 Express 
Example 
h b r r l s s s s s s a a a a s E s s s X  t 
 
Table 4: 
Message Type b (Ademco 4-1 Express) Byte Description 
 
# Title 
Description 
Header Character (
h
Optional. Check with the computer automation software for compatibility. 
2 Message 
Type 
3-4 
Receiver Number 
Receiver gateway number from 01 to 99.  
5 Line/Group 
Number 
Line number in the receiver gateway that sent the message. 
6-11 
Spaces 
Six spaces.  
12-15 Account 
Number 
Account number, four digits.  
16 
Space 
One space.  
17 E 
Event Code, “A” as the default. 
18-20 
Spaces 
Three spaces.  
21 X 
Zone number.  
22 
Trailer Character 
Typically, this is HEX 14. 
 
3.1.3 
Ademco 4-2 Express (Message Type c) 
D6500 Byte Description 
10  11  12  13  14  15  16  17  18  19  20  21 
22 
4-2 Express 
Example 
h c r r l s s s s s s a a a a s E s s X Y  t 
 
Table 5: 
Message Type c (Ademco 4-2 Express) Byte Description 
 
# Title 
Description 
Header Character (
h
Optional. Check with the computer automation software for compatibility. 
2 Message 
Type 
3-4 
Receiver Number 
Receiver gateway number from 01 to 99.  
5 Line/Group 
Number 
Line number in the receiver gateway that sent the message.  
6-11 
Spaces 
Six spaces.  
12-15 Account 
Number 
Account number, four digits.  
16 
Space 
One space. 
17 E 
Event Code, “A” as the default. 
18-19 
Spaces 
Two spaces.  
20-21 XY 
Event code and zone number.  
22 
Trailer Character 
Typically, this is HEX 14.