Bosch Appliances Network Router D6100 User Manual

Page of 168
Conettix D6600/D6100 | Computer Interface Manual | 3.0  
Computer Communication Protocols 
 
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 
19 
 
3.1.18  Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) 
D6500 Byte Description 
10  11  12  13  14  15  16  17  18  19  20  21  22 
h h r r l a a a a a a s C C C C s C C C C s 
23  24  25  26  27  28  29  30  31  32  33  34  35  36  37  38  39  40  41  42  43  44 
Scancom  
4-24-1 Example 
C C C C s C C C C s C C C C s C C C C s C t 
 
Table 20: 
Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) Byte Description 
 
# Title 
Description 
Header Character (
h
Optional. Check with the computer automation software for compatibility. 
2 Message 
Type 
3-4 
Receiver Number 
Receiver gateway number from 01 to 99.  
5 Line/Group 
Number 
Line number in the receiver gateway that sent the message.  
6-11 
Account Number 
Account number up to six digits. Account numbers less than six characters are right 
aligned with leading ASCII spaces.  
12 Space 
One space.  
13-16 
CCCC 
Channels 1 to 4.  
17 Space 
One space.  
18-21 
CCCC 
Channels 5 to 8.  
22 Space 
One space.  
23-26 
CCCC 
Channels 9 to 12.  
27 Space 
One space.  
28-31 
CCCC 
Channels 13 to 16.  
32 Space 
One space.  
33-36 
CCCC 
Channels 17 to 20.  
37 Space 
One space.  
38-41 
CCCC 
Channels 21 to 24.  
42 Space 
One space.  
43 
Supervisory channel.  
44 Trailer 
Character 
Typically, this is HEX 14.