3.1.21  SIA (Message Type S) 
Defined Messages 
D6500 Byte Description 
10  11  12  13  14  15  16  17  18  19  20 
21 
22 
SIA Example 
h  S r r l [ # a a a a | E M M Z Z Z Z / ***] t 
 
Table 23: 
SIA (Message Type S) Byte Description 
 
# Title 
Description 
Header Character 
(
h
)    
Optional.  Check with the computer automation software for compatibility.  
Message Type    
3-4 
Receiver Number    
Receiver gateway number from 01 to 99.  
5 Line/Group 
Number 
Line number in the receiver gateway that sent the message.   
Open bracket.  
7 # 
#  
8-11 
Account Number 
Up to sixteen digits may be used in the account number.   
12 | 
Separator, indicates more data positions after account number. 
13 
SIA block code.   
14-15 Event 
Code 
SIA Event code.  
16-19 
Zone 
Zone number.   
20 / 
Separator.  
21 
***] 
Next block of data.   
22 Trailer 
Character 
Typically, HEX 14. 
Undefined Messages 
When an SIA message contains unprintable characters (unprintable characters are out of ASCII range 0x32-0x7E) 
or without an account block: 
D6500 Byte Description 
.    .   . 
N-1 
 
 
 
 
 
 
 
 
 
 
SIA Example 
h S r r L [ data 
]  t                     
 
Table 24:    SIA (Message Type S) Byte Description 
 
# Title 
Description 
Header Character 
(
h
)    
Optional. Check with the computer automation software for compatibility. 
Message Type    
3-4 
Receiver Number    
Receiver gateway number from 01 to 99.  
5 Line/Group 
Number 
Line number in the receiver gateway that sent the message.   
Open bracket.  
7-(N-2) data 
The received SIA message contains hex characters either with or without account 
portion. 
Trailer Character 
Typically, HEX 14.