ADT SIA (Message Type <TAB>) 
SIA Mode Description 
ADT SIA 
Example 
<LF><CRC><TAB><sequence#><receiver#><line#>[#aaaa|<E><damm-dd-
yytihh:mm:ss>data]<CR> 
 
Table 47: 
ADT SIA (Message Type <TAB>) Byte Description 
 
Title Description 
LF 
Standard line feed character.  
CRC 
Cyclical redundancy check number.  
Message Type 
09 hex <TAB>. 
sequence# 
The message sequence number. The valid sequence number range is 0001 to 9999. 
receiver# 
The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600/D6100. 
line# 
(Line/Group #) 
The line number of the line in the receiver gateway that sent the message. Valid digits are 00 
to 99. The receiver uses Line 0 (zero) for internal messages. 
account# 
The communicator's account number up to sixteen digits. 
Event Code (refer to Appendix G ADT SIA Report Codes on page 149). 
damm-dd-yytihh:mm:ss 
Date and time. 
Data 
This field contains message data codes such as event type, area number, point number, 
identification number. 
 
3.2.7 
Caller ID (Message Type <TAB>) 
SIA Mode Description 
SIA Example 
<LF><CRC><TAB><sequence#><receiver#><line#>[&TTTTTTTTTTTTTTTT]<CR> 
 
Table 48: 
Caller ID (Message Type <TAB>) Byte Description 
 
Title Description 
LF 
Standard line feed character.  
CRC 
Cyclical Redundancy Check number.  
Message Type 
<TAB> 
sequence# 
The message sequence number. The valid sequence number range is 0001 to 9999. 
receiver# 
The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. 
line# 
(Line/Group #) 
The line number of the line in the receiver gateway that sent the message. Valid digits are 00 
to 99. The receiver uses Line 0 (zero) for internal messages. 
Origin ID Block.  
Up to 16-digit Caller ID.