3.2.8 
CFSK (Message Type I)  
SIA Mode Description 
CFSK Example 
<LF><CRC><I><sequence#><Receiver#><line#>[#aaaaaa|TTEE]<CR> 
 
Table 49: 
CFSK (Message Type I) Byte Description 
 
Title Description 
LF 
Standard line feed character.  
CRC 
Cyclical redundancy check number.  
Message Type 
I (Capital I). 
sequence# 
The message sequence number. The valid sequence number range is 0001 to 9999. 
receiver# 
The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. 
line# 
(Line/Group #) 
The line number of the line in the receiver gateway that sent the message. Valid digits are 00 
to 99. The receiver uses Line 0 (zero) for internal messages. 
account # 
The communicator's account number, up to six digits. 
TT 
Event code.   
EE 
Zone/User ID.  
 
3.2.9 
Common Formats (Message Type <TAB>) 
Defined Messages 
SIA Mode Description 
SIA Example 
<LF><CRC><TAB><sequence#><receiver#><line#>[#aaaaaaaaaaaaaaaa|data]<CR> 
 
Table 50: 
Common Formats (Message Type <TAB>) Byte Description 
 
Title Description 
LF 
Standard line feed character.  
CRC 
Cyclical Redundancy Check number.  
Message Type 
09 hex <TAB> 
sequence# 
The message sequence number. The valid sequence number range is 0001 to 9999. 
receiver# 
The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. 
line# 
(Line/Group #) 
The line number of the line in the receiver gateway that sent the message. Valid digits are 00 
to 99. The receiver uses Line 0 (zero) for internal messages. 
account# 
The communicator's account number up to sixteen digits. 
Data 
This field contains message data codes such as event type, area number, point number, 
identification number, and so on.   
The receiver gateway sends the 3-1, 4-1, 4-2, single round, double round, extended pulse formats, BFSK, Modem 
II or Modem IId messages in either D6500 Mode or SIA Mode, depending on the program option selected. The 
receiver gateway also sends internal and Modem IIIa² messages in either D6500 mode or SIA mode, depending 
on the programmable option selected. Refer to Appendix B: Internal Messages on page 58 and Appendix C: 
Modem IIIa2 Messages
 on page 61 for a list of the messages and their descriptions. 
 
Figure 12:  Message sent to printer 
MM/DDsHH:MMsLxxSIA ACCT aaaa 
+++ TEXT 1 
+++ TEXT 2