Bosch Appliances Network Router D6100 User Manual

Page of 168
Conettix D6600/D6100 | Computer Interface Manual | 3.0  
Computer Communication Protocols 
 
 
46 
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 
 
 
Table 77: 
Silent Knight FSK1 Optional Outputs (continued) 
 
Report Code 
Description 
To Automation 
Note 
90 
Opening 
OP00 
90 
 
91 to 99 
Opening 01 to 09 
OP0x 
91 to 99 
 
 
3.2.24  Silent Knight FSK2 (Message Type m) 
SIA Mode Description 
Silent Knight 
FSK2 Example 
<LF><CRC><m><sequence#><receiver#><line#>[#aaaaaa| 
EEZZ”ECZZ”EEZZ”EEZZ”EEZZ”EEZZ”EEZZ”EEZZ]<CR> 
 
Table 78: 
Silent Knight FSK2 (Message Type m) Byte Description 
 
Title Description 
LF 
Standard line feed character.  
CRC 
Cyclical redundancy check number.  
Message Type 
m  
sequence# 
The message sequence number. The valid sequence number range is 0001 to 9999. 
receiver# 
The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100.  
line# 
(Line/Group #) 
The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 
99. The receiver uses Line 0 (zero) for internal messages. 
account # 
The communicator's account number has up to six digits. 
EEZZ”EEZZ”EEZZ”EEZZ”
EEZZ”EEZZ”EEZZ”EEZZ
 
Up to eight reports. One report has four digits: one-digit event code, one-digit condition code, 
and two-digit zone code. The quote (“) is the separation character.