Bosch Appliances Network Router D6100 User Manual

Page of 168
Conettix D6600/D6100 | Computer Interface Manual | 3.0  
Computer Communication Protocols 
 
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 
49 
 
3.2.28  Varitech FSK 4-2 (Message Type <TAB>) 
SIA Mode Description 
Varitech FSK 4-2 
Example 
<LF><CRC><TAB><sequence#><receiver#><line#>[#aaaa|data]<CR> 
 
Table 83: 
Varitech FSK 4-2 (Message Type <TAB>) Byte Description 
 
Title Description 
LF 
Standard line feed character.  
CRC 
Cyclical redundancy check number.  
Message 
<TAB> 
sequence# 
The message sequence number. The valid sequence number range is 0001 to 9999. 
receiver# 
The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100.  
line# 
(Line/Group #) 
The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 
99. The receiver uses Line 0 (zero) for internal messages. 
account # 
The communicator's account number has four digits. 
data 
The event type and two-digit zone number. 
 
3.2.29  VONK (Message Type V) 
SIA Mode Description 
VONK Example 
<LF><CRC><V><sequence#><receiver#><line#>[#aa|123456789ABCDEFG]<CR> 
 
Table 84: 
VONK (Message Type V) Byte Description 
 
Title Description 
LF 
Standard line feed character.  
CRC 
Cyclical redundancy check number.  
Message Type 
sequence# 
The message sequence number. The valid sequence number range is 0001 to 9999.  
receiver# 
The receiver gateway that sent the message.  Valid digits: 01 to 99 for D6600/D6100.  
line# 
(Line/Group #) 
The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 
99. The receiver uses Line 0 (zero) for internal messages. 
account # 
The communicator's account number has two digits. 
Data 
Status of zones 1 to 16. If the zone is closed, a “.” (Period) appears in this position. If the zone 
is open, any digit from 1 to G appears in this position.