Bosch Appliances Network Router D6100 User Manual

Page of 168
Conettix D6600/D6100 | Computer Interface Manual | 2.0  
Making the Right Connection 
 
 
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 
 
2.0   Making the Right 
Connection 
2.1 
COM3 DB9 Connector 
The COM3 Port uses a standard DB9 female 
connector. The suggested connection to the computer 
is shown in Figure 4 to Figure 6
When connecting data terminal equipment (DTE) 
together (such as a COM1 port to PC serial port), a 
null-modem cable must be used. One possible 
configuration for a null-modem cable is shown in 
Figure 4
 
Figure 4: 
Null Modem Cable Configuration 
1
2
3
4
6
7
8
9
1
2
3
4
6
7
8
9
DTE
DB-9 Pin
DTE
DB-9 Pin
5
5
 
 
When connecting data terminal equipment to data 
communication equipment (DCE) (such as the 
D6600/D6100 COM port to a modem), a modem 
cable should be used (such as a straight-through cable 
shown in Figure 5). 
 
Figure 5: 
Straight-through Modem Cable 
Configuration 
DTE
1
2
3
4
5
6
7
8
9
DCE
8
3
2
20
7
6
4
5
22
 
 
Each pin of the modem cable is defined in Figure 6
 
Figure 6: 
Modem Cable Pin Definitions 
1
2
3
4
5
6
7
8
9
 
1 -  Data carrier detect 
(DCD) 
2 -  Receive (RX) 
3 -  Transmit (TX) 
4 -  Data terminal ready 
(DTR) 
5 -  Signal-ground 
(SIG-GND) 
6 -  Data set ready 
(DSR) 
7 -  Ready to send 
(RTS) 
8 -  Clear to send 
(CTS) 
9 -  Ring indicator (RI) 
 
2.2 
Selecting Program Options in the 
D6600/D6100 
Use the D6600/D6100 keypad or the D6200 
Programming Software to program the receivers. 
Below are the recommended selections for 
programming when connecting the receivers to an 
automation system. Additional selections can be found 
in the D6600/D6100 Program Entry Guide 
(P/N: 4998122702). 
Table 1: 
Recommended Programming 
Selections 
 
Receiver 
Gateway 
Number 
Selects a number (01 to 99) that is 
included in every message to the 
computer in both D6500 and SIA modes  
Enable computer output messages in the 
selected format: 
SIA 
computer interface standard 
format, recommended  
(expanded reporting 
capabilities) 
Output 
Format 
D6500 
21-character format output  
Baud Rate 
Use maximum speed supported by PC 
Link Test 
Tests if a supervision signal can be sent 
and received from the central station by 
the receiver