Bosch Appliances Home Security System DS7400XIV4-EXP User Manual
DS7400XiV4-EXP | User Guide | 9.0 Error Displays
EN | 26
Bosch Security Systems | 6/05 | 4998154961B
9.1 System
Faults
System faults are designated as shown in Table 24:
Table 24: System Faults
[#][8][7] displays:
[#][8][9] displays:
RAM Fault
System Fault 01
ROM Fault
System Fault 02
EEPROM Fault
System Fault 03
Ground Fault
System Fault 04
2Ph/Bell Fault = loss of communication to bell/dual phone line module
System Fault 10
Line 1 Fault = bell/dual phone line module phone line 1 fault
System Fault 11
Line 2 Fault = bell/dual phone line module phone line 2 fault
System Fault 12
Bell Fault = bell/dual phone line module bell circuit fault
System Fault 13
Aux. Relay Fault = bell/dual phone line module aux. relay fault
System Fault 14
Oct. Relay Fault = loss of communication to octal relay module
System Fault 20
Reserved for older control panels
System Fault 50
AR IB Queue Full = modem buffer full
System Fault 51
AR Host Down = network data switch down
System Fault 52
AR Unreg. Modem = modem not registered
System Fault 53
AR Power Fail = power source below defined threshold
System Fault 54
AR Network Lost = loss of network
System Fault 55
AR Modem HW Err = modem hardware error
System Fault 56
AR Modem SW Err = modem software error
System Fault 57
AR Opt. Bus Err = loss of communications to alternate communication module
System Fault 58
AR Corrupt MSG = message error
System Fault 59
AltComm A Tx Err
SerialBI/F Fault
SerialB Tx Error
SerialB Rx Error
SerialBFlowError
AltComm A Error
AltComm B Error
AltComm B Tx Err
AltComm A Flow
AltComm B Flow
System Fault 60