Bosch Appliances Home Security System DS7400XIV4-EXP User Manual

Page of 40
DS7400XiV4-EXP | User Guide | 10.0  
Testing Your System 
EN | 28 
 
 
Bosch Security Systems | 6/05 | 4998154961B 
 
10.2 Battery 
Tests 
If a power failure occurs, your control panel has a backup battery that continues to power the control panel for 
many hours. The control panel automatically recharges the battery when power is restored. 
In addition to the automatic battery test performed every 2 minutes, you can also test the battery manually. This 
test also uses the battery to manually activate all the system sounders for 2 seconds ([PIN][#][8][5] only). If the 
battery voltage is low, a battery fault occurs (refer to Section 9.0 Error Displays on page 25). 
If you perform this test from a Master keypad, the keypad must be in Single Partition Mode. System Tests are not 
available from RF (wireless) keypads. 
 
Table 26: Zone Test 
 
 
 
 
Type of Test  
Command Sequence 
What Happens 
What To Do 
Local Battery/ 
Sounder Test 
[PIN][#][8][5] 
•  All keypad LEDs turn on. 
•  The keypad sounder and all alarm 
sounding devices operate for 2 seconds. 
•  If the test fails, the control panel indicates 
a control problem. Refer to Section 9.0 
Error Displays
 on page 25. 
•   If the sounder fails to operate 
or if the battery fails, contact 
your installing company. 
Battery Test 
[PIN][System Reset] 
•  The control panel performs a battery test. 
•  The control panel reports a Low Battery 
or a Low Battery Restoral is necessary. 
•  Contact your installing 
company if a low or missing 
battery is reported. 
 
10.3 Communicator 
Test 
This test is available only if your system sends alarms and system information to a monitoring service, and is 
programmed by the installing company to permit communicator tests. You can perform this test from a Master 
Keypad. The account code for Area #1 is used. System tests are not available from RF (wireless) keypads. 
A long beep initially sounds to acknowledge the start of the test. If the test is successful, the sounder again sounds 
one long beep. If the test fails, the keypad sounder turns ON continuously. To silence the sounder, enter your 
[PIN] and press the [#] key or the [*] key. 
 
Table 27: Communicator Test 
 
 
 
 
Type of Test  
Command Sequence 
What Happens 
What To Do 
Communicator 
Test 
[PIN][#][8][2] 
 
•  A long beep sounds. 
•  A “Test” report is sent to the monitoring 
service. 
•  If the test fails, the keypad sounder 
operates continuously. 
To silence the sounder, press 
[System Reset].  
Note: This test can take several 
minutes to complete because the 
control panel attempts ten calls.