Bosch Appliances Home Security System D9112B User Manual

Page of 96
D9112B | Program Entry Guide | 10.0  Skeds 
EN | 90 
 
 
Bosch Security Systems | 2/04 | 74-06145-000-D 
 
 
Default  Description 
Sub-prompt 
Selection 
S## Defer Test
 
Yes 
No 
Defer the 
Test
 report. 
Send the 
Test
 report on 
schedule. 
9 Test 
Report. 
This function 
generates a 
Test
 report from Area 
1. The report is sent to the Phone(s) 
programmed for 
Test
 and 
Status
 
reports in Phone Routing (see 
Ph# 
Test/Stat Rpt
). 
If 
Expand Test Rpt
 in Phone is 
programmed YES, the 
Test
 report 
also includes the following system 
events if the panel is currently in the 
condition listed: Log Threshold, 
Log Overflow, Point Bus Failure, 
Successful Local Programming, 
Failure to Call RAM, User Code 
Tamper, SDI Failure, 
Communications Failure, AC 
Failure, Battery Missing, Battery 
Low, Parameter Checksum Failure. 
The 
Test
 report can be deferred if 
any other report was sent since the 
last 
Test
 report. To defer the 
Test
 
report, program 
Defer Test. 
The 
Test
 report can be sent every 
hour beginning at the time 
scheduled in 
S## Time
. To send a 
Test
 report every hour, program 
Hourly Rpt
.
 
S## Hourly Report
 
Yes 
 
No 
Send the 
Test
 report every 
hour. 
Send the 
Test
 report only 
as scheduled. 
10 Status 
Report. 
This function 
generates a 
Status
 report for each 
area that is enabled. The report is 
sent to the Phone(s) programmed 
for 
Test
 and 
Status
 reports in Phone 
Routing (see 
PH# Test/Stat Rpt
). 
The 
Status
 report can be deferred if 
any other report was sent since the 
last 
Status
 report. To defer the 
Status
 report, program 
Status 
Report
.
 
S## Defer Status
 
Yes 
No 
Defer the 
Status
 report. 
Send the 
Status
 report on 
schedule.