Bosch Appliances Home Security System D9412GV2 User Manual

Page of 74
D9412GV2/D7412GV2 | Operation and Installation Guide | 12.0  SDI Devices 
 
58 
Bosch Security Systems, Inc. | 5/05 | F01U003641B 
 
12.4.1 Access 
Using Wiegand style cards or tokens, the D9210B can 
allow access for up to 996 cards or tokens on the 
D9412GV2, and up to 396 on the D7412GV2. User 
access authority can be configured to restrict access to 
certain doors or to certain periods of time. The reading 
of access cards, in addition to granting access, can 
control whether the system disarms. Used with the 
D9412GV2, the D9210B recognizes 249 master users 
by user name, passcode, and access authority. The 
D9210B recognizes 99 master users when used with the 
D7412GV2. Each master user supports three sub-users 
with unique cards or tokens having the same access 
level as the master user. 
12.4.2 Switch 
Settings 
Switches on the D9210B assign a unique address (1 to 
8) to each module. Table 24 shows the correct switch 
setting for each D9210B address. 
Table 24: 
Address Switch Settings for  
Access Control Module 
 
DIP Switch Settings 
Door Module 
Addresses 
1 2 3 4
1
 
5
6
2
 
ON 
ON 
ON 
 
ON 
ON 
2 OFF 
ON 
ON 
 
ON 
ON 
---------------D7412GV2 Maximum--------------- 
ON OFF ON 
 
ON  ON 
OFF 
OFF 
ON 
 
ON 
ON 
ON ON OFF    ON ON 
OFF 
ON 
OFF 
 
ON 
ON 
7 ON 
OFF 
OFF 
 
ON 
ON 
OFF 
OFF 
OFF 
 
ON 
ON 
1 
Switch 4, Fail Safe Mode: 
 
ON =  If SDI bus fails, relay energizes. 
OFF = If SDI bus fails, relay de-energizes. 
2 
Switches 5 and 6 must remain in the ON position. 
 
 
12.5  SDI Address 80 
SDI Address 80, available on the D9412GV2 and 
D7412GV2 Control Panels, allows for two-way SDI to 
RS-232 information. This address is used with home or 
building automation software. A D9133 Serial Interface 
Module is required for this application. 
12.5.1  Serial Interface Modules (SIMs) 
The DX4010i RS-232 Serial Interface Module and the 
D9133 Serial Interface Module are four-wire powered 
SDI devices that provide connection for RS-232 
devices to the D9412GV2 and D7412GV2 Control 
Panels. They use a specific communication protocol 
that is provided upon request. Contact Bosch Security 
Systems Technical Support Monday through Friday 
from 5 AM to 5 PM EST at 888-886-6189. 
The DX4010i can be installed up to 305 m (1000 ft.) 
from the control panel, using 0.8 mm (22 AWG) wire. 
The DX4010i was not investigated by UL. Do not use 
DX4010i in UL Listed installations. 
The D9133 can be installed up to 305 m (1000 ft.) from 
the control panel using 1.2 mm (18 AWG) wire. The 
D9133 was not investigated by UL. Do not use D9133 
in UL Listed installations. 
12.5.2 Address 
Settings 
No jumper settings are required for the D9133 (SDI 
Address 80) for home or building automation purposes 
(Figure 26). Remove the jumper shunts for this purpose. 
 
Figure 26:  D9133 Jumper Setting for Address 80 
1
2
3
4
80
 
 
The DX4010i has specific DIP switch settings for SDI 
Address 80 when home or building automation is 
desired. Figure 27 on page 59 shows the correct settings 
for Address 80.