Bosch Appliances Home Security System D9412GV2 User Manual

Page of 74
D9412GV2/D7412GV2 | Operation and Installation Guide | 12.0  
SDI Devices 
 
Bosch Security Systems, Inc. | 5/05 | F01U003641B 
59 
 
Figure 27:  DX4020i DIP Switch Settings 
SER
Rx
Tx
BUS
Rx Tx
LED
 ENABLE
DB9 GND
ENABLE
P1
P6
P2
P3
1
2
4
8
16
32
64
128
ON
1
2
3
4
5
6
7
8
1
2
4
8
16
32
64
128
ON
1
2
3
4
5
6
7
8
1
2
3
4
 
1 -  Address DIP switches 
2 -  OFF position 
3 -  ON position 
4 -  SDI Address 80 switch settings 
 
12.5.3 Supervision 
Supervision of the serial interface module is available 
through programming. Supervision is not required to 
use a DX4010i or a D9133.  
If supervised, and the serial interface module does not 
respond to control panel supervision polls, the control 
panel sends an SDI Failure Report to the receiver. If it 
fails to communicate with the DX4010i or the D9133, 
SERVC SDI 80
 displays at the keypad. The SDI 
Failure Report includes the address of the troubled 
module indicating which module needs service. 
12.6  SDI Address 88 
SDI Address 88 is available with the D9412GV2 and 
D7412GV2 Control Panels and is used for several 
different applications. When using SDI Address 88, 
connect only one listed device at a time. 
12.6.1  D9133DC Direct Connect Programming 
Module 
Use the D9133DC Direct Connect Programming 
Module to handle local programming of the 
D9412GV2 and D7412GV2 Control Panels. In 
addition, the D9133DC allows diagnostic and history 
retrieval. D9133DC is not UL Listed. 
Connecting the D9133DC 
1.  Configure D9133DC for SDI Address 88. To 
program the control panel when the reset pin is in 
the unlocked position, program Enable SDI RPS to 
Yes in the GV2AUX handler. 
2.  Connect D9133DC to Com Port 1 or Com Port 2 
on the PC. The D9133DC has a DB-9 female serial 
connector. A null-modem cable must be purchased 
separately to connect the D9133DC to a PC. 
3.  Using 0.8 mm (22 AWG) or 1.2 mm (18 AWG) 
wire, connect the D9133DC SDI terminals (SDI 
PWR, SDI A, SDI B, and SDI COM) to the 
control panel’s SDI terminals (Terminals 29 to 32). 
To send or receive the control panel’s program, place 
the Reset Pin in the 
Locked or Unlocked position. 
 
Locking the Reset Pin when programming 
the control panel improves the uploading 
and downloading times. 
 
Used as an External Modem 
The D9133DC can operate as an external modem 
when using Remote Programming Software (RPS) with 
the control panel. Refer to the D9412GV2/D7412GV2 
Program Entry Guide
 (P/N: F01U003636) for 
programming details.  
12.6.2  Network Interface Modules 
The Bosch Security Systems DX4020 Network 
Interface Module and D9133TTL-E Network Interface 
Module are four-wire powered SDI devices that 
provide connection for two-way communication over 
Ethernet networks to D9412GV2 and D7412GV2.  
For programming information on enhanced 
communications, refer to the D9412GV2/D7412GV2 
Program Entry Guide 
(P/N: F01U003636). 
The DX4020 can be installed up to 305 m (1000 ft) 
from the control panel using 0.8 mm (22 AWG) wire. 
The D9133TTL-E can be installed up to 305 m  
(1000 ft) from the control panel using 1.2 mm  
(18 AWG) wire.