Bosch Appliances Home Security System D9412GV2 User Manual

Page of 74
D9412GV2/D7412GV2 | Operation and Installation Guide | Appendix A: System Wiring Diagrams, Issue A 
 
Bosch Security Systems, Inc. | 5/05 | F01U003641B 
69 
 
Figure 39:  D7412GV2, SDI Devices 
+
-
EARTH GROUND
COMMON
BATTERY NEGATIVE ONLY
Maximum Charging
Current 1.4 Amps.
BATTERY POSITIVE ONLY
RELAY A
RELAY B
RELAY C
+ AUX POWER
CLASS 2 TRANSFORMER
16.5 VAC 40 VA 60 Hz
Model D1640
Internally Fused - Do Not short
Requires Unswitched Outlet
Do Not Share With Other Equipment
PROGRAMMABLE
ALARM OUTPUTS
Terminals
Requires Optional
Model D136 Relay
In ALT ALARM
& SW AUX
&
7
8
GROUND FAULT DETECT
Enabled
Disabled
D8125
D8128D
D8129
D9133TTL-E
or
DX4020
D9131A
D9210B
D1260
D1257
D1256
D1255
PERIPHERAL DEVICE CONNECTIONS
RED
POWER +
YELLOW
DATA BUS A
GREEN
DATA BUS B
BLACK
COMMON
ZONEX OUT 1
ZONEX IN 1
NFPA
Style 3.5
Signaling
Line
Circuits
D7412GV2
PHONE
LED
RED
ON when
communicating
OFF when idle
PHONE LINE SEIZED
TIP
RING
TELCO
PERIPHERAL DEVICE CONNECTIONS
RED
POWER +
YELLOW
DATA BUS A
GREEN
DATA BUS B
BLACK
COMMON
ZONEX OUT 1
ZONEX IN 1
NFPA
Style 3.5
Signaling
Line
Circuits
GRN
D5200/D5360
PROG CONN
Point 8
S3 Option
Closed = 1K
Ω
 EOL
Normal Operation
Open =AB-12 UL
Bell Box 220 K
Ω
NOT USED
25
NOT USED
ZONEX POWER +
ZONEX COMMON
26
24
23
 
1 -  Up to 8 supervised 
2 -  Up to 3 supervised 
3 -  Power limited, supervised 
4 -  POPEX 1 
5 -  Up to 119 D9127U/T POPITs or up to 63 
D8127U/T POPITs 
6 -  Zonex 1: 15 D8128Ds 
7- 
Zonex 1: Up to 8 maximum 
 
 
All external connections except Terminal 5 (battery positive) are power limited.