Off-board Points
8.3.6
POPIT Module Point Assignments
Seven switches on each D9127U/T POPIT (six on each D8127U/T POPIT) assign the module to a point number. POPIT
switch settings are found in Point Assignment in the D7212G Program Record Sheet (P/N: 4998138542)See Figure 14.
8.3.7
Program Record Sheet
The eight columns on the D7212G Program Record Sheet (P/N: 4998138542) contain the following information:
• First column (POPIT Switch Settings): the switch settings for the D8127 POPITs. Switches are numbered 1 to 6,
left to right on the D8127 POPIT. Switches are numbered 0 to 6, left to right on the D9127 POPIT. Set switches
with numbers that appear in the setting to the ON position. Set switches with a dash (-) in the switch position to
the OFF position. See Figure 14.
• Second column (Translation):  the translation of the point number into the ZONEX format. See Point User Flag
in  the D7212G Program Entry Guide (P/N: 4998138538) for an explanation of this feature.
• Third column (Point #): the point number as it is displayed at command centers.
• Fourth column (Point Index): See Point Index Parameters in the D7212G Program Entry Guide (P/N: 4998138538)
for an explanation of the point index.
• Fifth column (Area Assign): the area the point is assigned to.
• Sixth column (Debounce): the Debounce Count for the point. See Debounce Count in the D7212G Program Entry
Guide (P/N: 4998138538).
• Seventh column (BFSK/Relay Entry): the BFSK/Relay report code. It is the point number reported for this point
when the panel is using the BFSK format. Additionally, this may be used as a summary relay option (see Point
Assignment 
in the D7212G Program Entry Guide [P/N: 4998138538]).
• Eighth column (Custom Point Text): the
text displayed at command centers for the point. The text is transmitted to the receiver when the panel is using
the Modem IIIa
 format.
D7212G
Default values are shown in ( ) or in bold
RADXPNTS Handler
Point Assignments (001 through 040)
POPIT Switch
Setting
Trans-
lation
Point
#
Point
Index
Area
Assign
Debounce
BFSK/
Relay
Custom Point Text
100
001
__ __
(1)
____
(2)
_____
(1)
____
P1 FIRE
___________________
200
002
__ __
(1)
____
(2)
_____
(2)
____
P2 PANIC
___________________
300
003
__ __
(1)
____
(2)
_____
(3)
____
P3 DELAY
___________________
400
004
__ __
(1)
____
(2)
_____
(4)
____
P4 FOLLOW ___________________
500
005
__ __
(1)
____
(2)
_____
(5)
____
P5 INSTANT ___________________
600
006
__ __
(1)
____
(2)
_____
(6)
____
P6 INSTANT ___________________
700
007
__ __
(1)
____
(2)
_____
(7)
____
P7 INSTANT ___________________
800
008
__ __
(1)
____
(2)
_____
(8)
____
P8 INSTANT ___________________
0 1 2 3 4 5 6
101
009
__ __
(1)
____
(2)
_____
(1)
____
P9
___________________
0 1 2 3 4 5 _
102
010
__ __
(1)
____
(2)
_____
(1)
____
P10
___________________
0 1 2 3 4 _ 6
103
011
__ __
(1)
____
(2)
_____
(1)
____
P11
___________________
0 1 2 3 4 _ _
104
012
__ __
(1)
____
(2)
_____
(1)
____
P12
___________________
0 1 2 3 _ 5 6
105
013
__ __
(1)
____
(2)
_____
(1)
____
P13
___________________
0 1 2 3 _ 5 _
106
014
__ __
(1)
____
(2)
_____
(1)
____
P14
___________________
0 1 2 3 _ _ 6
107
015
__ __
(1)
____
(2)
_____
(1)
____
P15
___________________
0 1 2 3 _ _ _
108
016
__ __
(1)
____
(2)
_____
(1)
____
P16
___________________
0 1 2 _ 4 5 6
109
017
__ __
(1)
____
(2)
_____
(1)
____
P17
___________________
0 1 2 _ 4 5 _
110
018
__ __
(1)
____
(2)
_____
(1)
____
P18
___________________
0 1 2 _ 4 _ 6
111
019
__ __
(1)
____
(2)
_____
(1)
____
P19
___________________
0 1 2 _ 4 _ _
112
020
__ __
(1)
____
(2)
_____
(1)
____
P20
___________________
0 1 2 _ _ 5 6
113
021
__ __
(1)
____
(2)
_____
(1)
____
P21
___________________
Figure 14: Program Record Sheet