Praesideo 3.5 | Installation and User Instructions | EN60849: 1998
en | 17
EN60849 - 4.3.2 Operational priorities
EN60849 - 4.4 Safety requirements
The use of these levels in descending order of priority 
will ensure that appropriate alarm signals and 
messages are provided first to the zones immediately at 
risk.
Compliant, if properly installed. Responsibility of the 
installer.
Requirement
Compliance
Signature
If the voice alarm system is capable of operation in fully 
automatic mode, a facility shall always be available to 
control:
a
The type of pre-recorded message being 
broadcast.
Compliant, if properly installed: 
Input contact configured to start a call with a pre-
recorded message.
Running message can be overridden by higher 
priority manually started messages.
b
The distribution of messages to different zones.
Compliant.
The numeric keypad PRS-CSNKP should not be used 
for zone selection for emergency purposes in a system 
that has to comply to EN60849:1998, because the 
LCD does not have a self-test function to check for 
correct operation.
c
Real-time instructions or information to occupants 
via the emergency microphone (if any).
Compliant, if properly installed. Manual selection of 
loudspeaker zones is supported. Adding or removing 
zones from a running call is supported.
Means shall be provided for manual intervention to 
override any automatically programmed functions. This 
shall apply both to the nature of the message being 
broadcast and to the distribution paths of the message. 
Thus, manual controls shall be provided at the central 
control point (and also at specified remote control 
points) to allow:
a
Starting or stopping of pre-recorded alarm 
messages.
Compliant, if properly installed. Running message can 
be overridden by higher priority manually started 
messages.
b
Selection of appropriate pre-recorded alarm 
messages.
Compliant, if properly installed. Manual selection of pre-
recorded alarm messages is supported.
c
Switching on or off, of selected loudspeaker zones.
Compliant, if properly installed. Manual selection of 
loudspeaker zones is supported. Adding or removing 
zones from a running call is supported.
d
Broadcasting of live messages via the emergency 
microphone (if any).
NOTE - The above controls may form part of an 
emergency detection control panel.
Compliant, if properly installed. Live calls from an 
emergency call station are supported.
The emergency control microphone shall have the 
highest level of priority for access to the voice alarm 
system, with provision to allow it to override all other 
broadcasts.
Compliant, if properly installed.
The PC call station (PRS-CSC) should not be used to 
make emergency announcements in a system that has 
to comply to EN60849:1998, because a PC does not 
comply to this standard for such use.
Requirement
Compliance
Signature
The safety requirements applying to emergency sound 
systems are given in IEC60065 or other appropriate 
IEC safety standards.
Compliant. Praesideo complies to IEC60065.
The mechanical construction of the system shall be 
such that under the influence of internally generated 
heat, explosion or implosion, however caused, no part 
shall cause injury to any person.
Compliant.
Where any part of the system is installed in areas with 
hazardous or explosive atmospheres, the relevant 
safety requirements of IEC60079 shall be met.
Responsibility of the installer. The Praesideo equipment 
itself does not comply to IEC60079.
Requirement
Compliance
Signature