Bosch 2000 User Manual

Page of 72
2000 Series | Program Entry Guide | 4.0 
Receiver 
EN | 16 
 
 
Bosch Security Systems | 7/05 | 35114F 
 
 
Table 2: continued 
 
Modem II Report 
Description 
CLOSING REPORT  
Closing Report when passcode is not used. Refer to the Passcode Rquired prompt in Section 
15.0 Passcodes.
 Using a Keyswitch or a remote programmer also sends this Closing Report 
with no user ID. 
CLOSING REPORT ID   
001 (-008) 
Closing Report with user ID for users 1 to 8. 
COMM FAIL 
PHONE (1-2) 
Communication Failure event. Refer to Phone 1, Phone 2 in Section 2.0 Phone. 
COMM RESTORAL  
PHONE (1-2) 
Successful communication after a Communication Failure event. Refer to Phone 1, Phone 2 in 
the Section 2.0 Phone. 
DURESS 
ID 008 
Passcode 8 used to turn the system on, turn the system off, or to silence an alarm. Refer to the 
Code 8 = Duress prompt in Section 15.0 Passcodes. 
EXIT ERROR 001 
(-024) 
When a point is faulted at the end of exit delay it generates an Exit Alarm. 
Exit Alarm Report from Points 1 to 24. 
FIRE ALARM POINT    
001 (-099) 
Fire Alarm Report from Points 1 to 24.  
FIRE ALARM CROSS 
POINT 001 (-024) 
Cross Point Fire Alarm Report from Points 1 to 24. 
MISSING ALARM POINT 
001 (-024) 
Missing Non-fire Controlled point, point is on (armed). Alarm response locally. 
MISSING TROUBLE 
POINT 001 (-024) 
Missing Non-fire Controlled point, point is off (disarmed), or 24-hour Non-fire point. Trouble 
response locally. 
OPENING REPORT  
Turning the system off with a keyswitch or a remote programmer sends this Opening Report 
with no User ID. 
OPENING REPORT ID   
001 (-008) 
Opening Report with User ID for users 1 to 8. 
OPEN FROM ALARM  
Turning the system off after an alarm with a Keyswitch point or a remote programmer sends 
this Opening Report with no User ID. 
OPEN FROM ALARM ID   
001 (-008) 
Opening Report after an alarm with User ID for users 1 to 8. 
PERM INST ARMED  
Remote programmer used to turn the system Part On with No Delays, or user turned the 
system Part On with No Delays and no passcode required. Refer to the Passcode Rquired 
prompt in Section 15.0 Passcodes
PERM INST ARMED ID  
001 (-008) 
User with ID shown (1 to 8) turned the system Part On with No Delays. 
PERM DLAY ARMED  
Remote programmer used to turn the system Part On (with Delays), or user turned the system 
Part On with Delays and no passcode required. Refer to the Passcode Rquired prompt in 
Section 15.0 Passcodes
PERM DLAY ARMED ID  
001 (-008) 
User with ID shown (1 to 8) turned the system Part On (with Delays).