Point Codes 
EN | 39 
 
Bosch Security Systems | 7/05 | 35114F 
 
 
Table 5: continued 
 
Display Selection 
Description 
Controlled, All,  
Delay 
When control panel is All On (armed), short or open starts entry delay if no 
Trouble option. Refer to Section 11.3 Digit 3, Point Options
All points must be normal (not faulted) or bypassed before control panel can 
be All armed. 
If an alarm occurs on these points within 2 minutes of a closing (exit time 
expired, Excursion/Exit included), the system sends a RECENT CLOSING 
message with the Alarm Report.  
If these points are faulted at the end of exit delay, the system waits a period 
equal to entry delay before sending an Alarm Report. If the system is not 
turned off, it sends an EXIT ERROR message with the Alarm Report. 
Missing Controlled points generate an alarm response when on, a trouble 
response when off. 
RF Tamper for a Controlled point generates an alarm response when on, a 
trouble response when off. 
Controlled, All,  
No Delay 
(Follower) 
When the control panel is All On (armed), and entry or exit delay times 
expire, a short or open causes an alarm response. These points follow the 
entry and exit delay and are ignored when faulted during these time periods. 
All points must be normal (not faulted) or bypassed before the control panel 
can be All armed. 
If an alarm occurs on these points within 2 minutes of a closing (exit time 
expired, Excursion/Exit included), the system sends a RECENT CLOSING 
message with the Alarm Report.  
If these points are faulted at the end of exit delay, the system waits a period 
equal to entry delay before sending an Alarm Report. If the system is not 
turned off, it sends an EXIT ERROR message with the Alarm Report. 
Missing Controlled points generate an alarm response when on, a trouble 
response when off. 
RF Tamper for a Controlled point generates an alarm response when on, a 
trouble response when off. 
Controlled, Part, Delay 
When control panel is All or Part On (armed) short or open starts entry 
delay if no Trouble option. Refer to Section 11.3 Digit 3, Point Options. 
Part points must be normal (not faulted) or bypassed before control panel 
can be Part armed. 
If an alarm occurs on these points within 2 minutes of a closing (exit time 
expired, Excursion/Exit included), the system sends a RECENT CLOSING 
message with the Alarm Report. 
If these points are faulted at the end of exit delay, the system waits a period 
equal to entry delay before sending an Alarm Report. If the system is not 
turned off, it sends an EXIT ERROR message with the Alarm Report. 
Missing Controlled points generate an alarm response when on, a trouble 
response when off. 
RF Tamper for a Controlled point generates an alarm response when on, a 
trouble response when off.