Bixolon Receipt Printer SRP-270 User Manual

Page of 85
 
Rev. 3.02 
- 24 -
SRP-270
3-5-1(f) S/W Flow Control 
When XON/XOFF flow control is selected, the printer transmits XON(ACSII 11h) or XOFF(ASCII 13h) signal 
through the TXD line. If the Printer is BUSY, the Printer transmits XOFF(ASCII 13h) to host through the TXD 
line. Then the host recognize that the Printer is BUSY. So, the host does not transmit a data to the Printer. If 
the Printer is released from BUSY, the Printer transmits XON(ASCII 11h) to host through the TXD line. Then 
the host recognize that the Printer is not BUSY. And the host transmit a data to the Printer. 
 
 Note : Refer to the Operation Manual about XON/XOFF flow control. 
 
 
 
3-5-2 RS-485 Serial Interface 
 
3-5-2(a) Specification 
Item 
Description 
Remark 
Data Transmission 
• Serial 
 
Synchronization • 
Asynchronous 
 
HandShaking 
(Flow Control) 
• H/W : DTR / CTS (Same as DSR) 
• S/W : XON / XOFF 
XON: ASC Code 11h 
XOFF: ASC Code 13h
Signal Level 
• Logic”1” : SD1-SD2 ≥ 0.2V, RD1-RD2 ≥ 0.2V 
• Logic”0” : SD1-SD2 ≤ 0.2V, RD1-RD2 ≤ 0.2V 
 
Baud Rate 
• 19200 / 2400 / 4800 / 9600 Bps 
 
Data Word Length 
• 7 Bit / 8 Bit 
 
Parity 
• None / Even / Odd 
 
Connector 
• DB25P Female (I/F PBA) 
 
Table 3-16 RS-485 Specification 
 
 Note : The HandShaking (Flow Control) / Data Word Length / Baud Rate / Parity functions depend 
on the DIP Switch settings. Refer to the User’s Manual. 
 
3-5-2(b) RS-232C I/F Cable 
Same as the appearance of RS-232C Cable 
 
3-5-2(c) Cable Connection 
   
 
Figure 3-8 RS-485 Cable Connection 
PRINTER 
SIDE 
HOST 
SIDE