Chapter 4: Configuration 
 
  
SHDSL – BiPAC 8520   
4-wired Mode 
2-wired Mode 
4-Wired Connection: BiPAC 8520 supports either 2-wire and 4-wires SHDSL connection. Activate the 
device to 4-wired by enabling the function; otherwise, disable it to be used as 2-wire mode connection.     
Note: When select 2-wired mode, only Port 1 settings need to be configured and the SHDSL (RJ-11 cable) must 
be connected to LINE 1 on the back of the device. 
 
Mode:  The SHDSL device can function as a CPE (Customer Premises Equipment) or CO (Central 
Office).    Select CPE mode when the BiPAC 8500 is connecting to your ISP.   
Back – to –back: it is a direct connection between two SHDSL devices which one is set to CPE and the 
other is CO by using a standard RJ-11 telephone cable.   
Annex Type: It is the DSL operating mode standard. Select Annex A or Annex B to support up to 
2.3Mpbs (for 2-wired mode) and 4.6Mpbs (for 4-wired mode). Select other annex such as Annex B_ANFP 
/ Annex A_B_ANFP, you may consult with your ISP first.   
Back – to –back: to be sure the Annex type is the same on the BiPAC 8520 and the remote router.   
Bit Rate Mode: The mode selections are Adaptive and Fixed.    Selecting the Adaptive mode, the best 
connection rate will be automatically negotiated with the CO / ISP.  Selecting the Fixed mode, the 
connection rate will be fixed to the specific fixed bit rate selected with the CO / ISP.     
Fixed Bit Rate: Specify the fix transfer rate when Fixed Mode is selected.  Specify the maximum 
transfer rate when Adaptive Mode is selected. Bit Rate range is from 72kbps ~ 2368kbps.   
Activate Line: Line active true is set by default.  Select false  to disable and true  to enable SHDSL 
SHDSL connection 
Note: Once Active Line is selected as false, you must enable the Active Line to true again and click Apply button to 
reactivate SHDSL connection.   
DSP FirmwareVersion: Display the SHDSL line code firmware version. 
Connected: Display current SHDSL line sync status. 
State: Display current SHDSL line status.   
Bit Rate: Display SHDSL line synch speed rate.   
Click Apply button to apply your changes 