5.0 RADXSKED 
5.1 Windows 
Use this programming module to define the windows 
for Opening and Closing and User Access. 
5.1.1  Opening and Closing 
Use these windows to set a schedule for disarming 
and arming. The disarming and arming schedules 
have several independent features: 
Suppress normal Opening or Closing Reports 
when A# Disable O/C in Windows is 
programmed as Yes
Generate a Fail to Open Report if the area is not 
disarmed on schedule when A# Fail To Open is 
programmed as Yes
Provide a warning tone and a PLEASE CLOSE 
NOW display at the keypad when it is time to arm 
the area. 
Generate a Fail to Close Report if the area is not 
armed on schedule when A# Fail To Close is 
programmed as Yes
Automatically arm the area at the end of the 
Closing Window when A# Auto Close is 
programmed as Yes
Opening and closing schedules can be set up 
independently. For example, if you want to use 
features provided only by Closing Windows, leave 
times blank in the Opening Windows prompts and 
program Closing Window times. 
A worksheet is provided at the end of this section for 
your convenience. Following the worksheet are 
examples of programmming Opening and Closing 
Windows for particular applications (refer to Table 38 
on page 112 through Table 42 on page 113). 
About the program record sheet: A column labeled 
Sked # is found in the program record sheet provided 
with the control panel. The numbers in that column 
appear in D6500 and D6600 reports and local printer 
reports when the window Begin Time executes. 
Window selections 1 through 8 correspond with odd-
numbered Skeds 41 through 55 for Open Window 
and correspond with even numbered Skeds 42 
through 56 for Close Window. For example, when the 
Opening Window for Window 1 executes, a Sked 41 
Executed event is generated. Refer to Table 34
 
Table 34: Window Selections 
 
Selectio
Sked #  Windo
Sked #  Windo
41 
Open 
42 
Close 
2 43 
Open 
44 
Close 
45 
Open 
46 
Close 
4 47 
Open 
48 
Close 
49 
Open 
50 
Close 
6 51 
Open 
52 
Close 
53 
Open 
54 
Close 
8 55 
Open 
56 
Close 
 
Window 
Default: 
Selection:  1 to 8 
Enter the window number you want to program. 
W# Sunday 
Default: 
No 
Selection: 
Yes or No 
Yes 
Activate this window on Sundays. 
No 
Do not activate this window on 
Sundays. 
This prompt and the next six day-of-the-week 
prompts select the days of the week the Opening and 
Closing windows are active. 
Exceptions: 
To prevent the windows from activating on certain 
days of the year, program Xept Holiday as Yes, and 
enable at least one Holiday Index. When Xept 
Holiday
 is Yes, the window executes on the days of 
the week programmed unless the Holiday Index 
designates the date as a holiday. 
If Opening and Closing Windows are only needed on 
certain days of the year, do not program the windows 
to execute on any days of the week. Instead, 
program Xept Holiday as No and select a Holiday 
Index with the days of the year you want the window 
to be active.