Bosch Appliances Video Game Controller D9412GV2 User Manual

Page of 158
D9412GV2/D7412GV2 | Program Entry Guide | 6.0  GV2AUX 
EN | 131 
 
 
Bosch Security Systems, Inc. | 10/08 | F01U003636-04 
5.  Type [A][T][E][0][Enter]. This eliminates echo, 
making all user input from this point forward 
invisible on the screen.  
 
 
 
When using an external modem, initialize 
it using the following HyperTerminal 
procedure on your computer. The 
6.  Type [A][T][&][W][0][Enter] to write the 
configuration to modem memory. The modem 
profile is saved to a file upon disconnection or 
power loss. 
 
HyperTerminal procedures can vary, 
depending upon the operating system. 
 
1.  In Windows
®
, open the HyperTerminal 
application. Select: 
Programs
AccessoriesCommunications 
The external modem is connected to the D9133DC 
Direct Connect Programming Module that is 
connected to the SDI bus using SDI Address 88. 
Refer to 
2.  Connect the modem to an available COM port. 
Figure 9 on page 132. A standard serial 
cable is required to connect the D9133DC to the 
external modem. 
3.  With the modem connected, select the 
appropriate COM port within HyperTerminal. 
Refer to  
If you are using an external modem for 
RPS communications, the enhanced 
4.  Set the baud rate of the modem to 9600. 
 
 
For Best Data Smart One V.92: 
Type [A][T][S][3][7][=][9][Enter] 
For US Robotics: 
Type [A][T][&][N][6][Enter] 
For other modems, consult the 
instructions provided with the device for 
the correct text string. 
 
communications and RPS functions using 
 
a NIM are disabled. 
 
Figure 8: Com Port Selection within HyperTerminal