Bosch Appliances Video Game Controller D9412GV2 User Manual

Page of 158
D9412GV2/D7412GV2 | Program Entry Guide | 2.0  GV2MAIN 
EN | 52 
 
 
Bosch Security Systems, Inc. | 10/08 | F01U003636-04 
 
 
CC# Area Assign 
Default: 
Selection:  1 to 8 
Blank is not a valid entry. 
Enter the area number where you are installing this 
keypad or keypads with this address and the same 
DIP switch settings. 
CC# Scope 
Default: 
Refer to the program record sheet 
Selection:  Panel Wide, Custom, No Keypad, 
Area, and Account 
Panel 
Wide 
A panel-wide keypad can view 
information and perform Arming and 
Disarming functions for all areas in 
the control panel. A panel-wide 
keypad can cross account 
boundaries. This is normally used 
with a master area. 
Account 
An Account keypad can view 
information, and perform Arming and 
Disarming functions for all areas with 
the same A# Acct Number, in Area 
Parameters. This is normally used for 
an associate area. 
Area 
An area keypad is restricted to 
viewing information and Arming or 
Disarming functions for the area to 
which it is assigned. 
Custom 
A custom keypad has no keypad 
restrictions. 
No 
Keypad 
No keypad installed at this address. 
CALL FOR SERVICE display shows, 
indicating the control panel is not 
polling this address. 
This program item is used to define the areas affected 
when an arming command is executed on this 
keypad, the areas this keypad can view, and the 
areas to which this keypad can move. 
Press the [SPACE] bar to scroll through the 
selections. Press [ENTER] when the correct selection 
appears in the display. 
 
 
In applications where keypads include 
more than one area, active alarms in 
remote areas must be acknowledged 
before arming or disarming the local area. 
 
The following prompt is visible only when 
you program CC## Scope to Custom. If 
you change the keypad scope selection 
 
to Custom from Panel Wide, Account, or 
Area, the settings from the previous CC# 
Scope
 selection become the default 
settings for the custom parameters in 
CC# A1 [through A8] in Scope. Before 
exiting from a custom program, check 
each area and ensure that it is enabled 
and disabled correctly. 
CC# A1[through A8] in Scope 
Default: 
Refer to the preceding important 
note  
Selection:  Yes or No 
Yes 
Include this area in the scope of this 
keypad. 
No 
Do not include this area in the scope 
of this keypad. 
Determines whether any of the eight areas (Area 1 to 
Area 8) and Doors (Door 1 to Door 8) are included in 
the scope of this keypad for viewing status, arming or 
disarming, and controlling doors from the keypad. 
CC# Entr Key Rly 
Default: 
Blank 
Selection:  1 to 128, A, B, C, and Blank 
Blank 
The [ENTER] key is not used to 
activate a relay. 
1 to 128, 
A, B, C 
Assign the relay number that 
activates when [ENTER] is pressed at 
this keypad after the user enters a 
valid pass code. 
Enter Key Relay: Program the relay number that 
activates momentarily for 10 sec when a user enters a 
valid pass code and presses the [ENTER] key on the 
keypad. Two events are generated when this function 
is used: RELAY ### SET with User ID, and RELAY 
### RESET without User ID. The system logs this 
action as two events. 
•  Entering a valid code and pressing [ENTER] 
silences a ringing bell. 
•  Using CC# Entr Key Rly for a low-level access 
control strike on a door does not shunt a point.