Bosch Appliances Video Game Controller D9412GV2 User Manual
D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN
EN | 65
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
User Cmd 9
Default:
P
Selection: Blank, E, or P
Function
No.
No.
Function Name
Alternate
Keystroke
Keystroke
24
User COMMAND
9
9
[COMMAND][9]
Use this function to activate an alarm programmed in
COMMAND 9 in the RADXPNTS Handler.
COMMAND 9 in the RADXPNTS Handler.
Bypass a Pt
Default:
P
Selection: Blank, E, or P
Function
No.
No.
Function Name
Alternate
Keystroke
Keystroke
25
Bypass a Point
[COMMAND][0]
Use this function to bypass individual points that have
P## Bypassable enabled. Points within the scope of
the keypad can be bypassed where the function is
entered (refer to Section 2.10.1 Keypad (Command
Center) Assignment) on page 51.
The control panel ignores alarms and troubles, and
does not display point faults when a point is
bypassed.
P## Bypassable enabled. Points within the scope of
the keypad can be bypassed where the function is
entered (refer to Section 2.10.1 Keypad (Command
Center) Assignment) on page 51.
The control panel ignores alarms and troubles, and
does not display point faults when a point is
bypassed.
Unbypass a Pt
Default:
P
Selection:
Blank, E, or P
Function
No.
No.
Function Name
Alternate
Keystroke
Keystroke
26
Unbypass a Point [COMMAND][0][0]
Use this function to unbypass individual points that
are programmed either P## FA Retrnable or P##
Bypass Returnable. Points within the scope of the
keypad can be unbypassed where the function is
entered (refer to Section 2.10.1 Keypad (Command
Center) Assignment) on page 51. The control panel
responds to alarms and troubles, and displays point
faults when a point is unbypassed.
are programmed either P## FA Retrnable or P##
Bypass Returnable. Points within the scope of the
keypad can be unbypassed where the function is
entered (refer to Section 2.10.1 Keypad (Command
Center) Assignment) on page 51. The control panel
responds to alarms and troubles, and displays point
faults when a point is unbypassed.
Reset Sensors
Default:
E
Selection: Blank, E, or P
Function
No.
No.
Function Name
Alternate
Keystroke
Keystroke
27 Reset
Sensors [COMMAND][4][7]
Use this function to activate the Reset Sensors
function for Fire or Intrusion points programmed as
P## Resettable in Section 4.1 Point Index on page
101. Points within the scope of the keypad where the
function is entered reset. Refer to Section 2.10.1
Keypad (Command Center) Assignment on page 51.
function for Fire or Intrusion points programmed as
P## Resettable in Section 4.1 Point Index on page
101. Points within the scope of the keypad where the
function is entered reset. Refer to Section 2.10.1
Keypad (Command Center) Assignment on page 51.
Change Relay
Default:
P
Selection: Blank, E, or P
Function
No.
No.
Function Name
Alternate
Keystroke
Keystroke
28 Change
Relays
[COMMAND][5][4]
Use this function to manually set and reset Relays 1
through 128 (1 through 64 in a D7412GV2) that are
installed in the system.
through 128 (1 through 64 in a D7412GV2) that are
installed in the system.
Remote Program
Default:
P
Selection: Blank, E, or P
Function
No.
No.
Function Name
Alternate
Keystroke
Keystroke
29
Remote
Programming
Programming
[COMMAND][4][3]
Use this function to start remote programming
software (RPS) sessions. When the phone is ringing
at the control panel, starting this function causes the
control panel to seize the line.
software (RPS) sessions. When the phone is ringing
at the control panel, starting this function causes the
control panel to seize the line.