Bosch KTS 200 User Manual

Page of 12
Bosch Diagnostics
1 689 989 001
2007-05-30
|
24  |  KTS 200  |  Operation
5.5
Software update
The software update is either performed using the 
“ESI[tronic] Startcenter” DVD or “online”.
The online software update (section 5.5.2) can only 
be performed with ESI[tronic] Startcenter version 
2007/3 or later.
5.5.1
Software update using the ESI[tronic] 
Startcenter DVD
Insert the “ESI[tronic] Startcenter” DVD in the DVD 
drive (e.g. “D:\”) on the PC/laptop.
Open the “Run” input field (select “Start >> Run...”
in the taskbar).
Enter
 D:\setup.exe
 and confirm by 
clicking <OK>.
The Setup routine is started.
Follow the installation instructions on the screen.
When installation is complete, restart the computer. 
Windows is shut down and ESI[tronic] 
Startcenter is restarted.
Connect the KTS 200 to the PC using the USB con-
necting lead.
Connect the KTS 200 to the mains using the power 
pack supplied.
The KTS 200 starts up. 
During the software update, the USB connection 
and the power supply to the KTS 200 may not be 
broken.
ESI[tronic] Startcenter: Open “KTS 200 >> Device 
information”.
Select an available update.
Select <Update>.
The system software is installed on the KTS 200.
0
1.
2.
3.
?
?
4.
?
5.
6.
?

7.
8.
9.
G
5.5.2
Online software update
Start “ESI[tronic] Startcenter”.
Open the “Settings >>Online updates” input 
window.
Enter the customer number and password and 
select <Next>.
If “Login” is not possible, check your proxy 
settings under “Settings >> User settings”.
Select an available update and start the software 
update.
Follow the installation instructions on the screen.
When installation is complete, restart the computer. 
Windows is shut down and ESI[tronic] 
Startcenter is restarted.
Connect the KTS 200 to the PC using the USB 
connecting lead.
Connect the KTS 200 to the mains using the power 
pack supplied.
The KTS 200 starts up. 
During the software update, the USB connection 
and the power supply to the KTS 200 may not 
be broken.
ESI[tronic] Startcenter: “KTS 200 >> Device 
information”.
Select an available update
Select <Update>.
The system software is installed on the KTS 200.
5.6
Faults
The KTS 200 may not be opened. Opening the 
KTS 200 erases its licensing data. It is then no 
longer possible to perform control unit diagnosis.
No communication with the control unit
The fault message “No system found” appears during 
control unit diagnosis.
Possible causes
What can you do?
Incorrect lead 
connected.
Check whether the correct 
lead has been used.
Incorrect pin selected 
in pin selection menu
Under “Start >> Diagnostic socket”, 
check which pin has to be used.
If problems of a different nature occur, please 
contact the ESI[tronic] service hotline directly.
1.
2.
3.
0
4.
5.
6.
?
7.
8.
?

9.
10.
11.
G

0