Beyerdynamic MCS 20 User Manual

Page of 76
MCS 20 – MCS 223 Microphone Unit
45
english
No.
Description
Value
range
Factory
setting
14
“FiFo” = “Requ” + “Free”:
0 = MCS 223 does not turn off another microphone unit
1 = MCS 223 turns off another microphone unit
0 or 1
1
15
“FiFo” = “Requ” + “Free”:
0 = MCS 223 is not turned off by another microphone unit
1 = MCS 223 is turned off by another microphone unit
0 or 1
1
16
Warning signal in the “Free” mode before the speech time has elapsed;
0 = no warning signal
0 ... 59 sec.
45
17
After the speech time has elapsed in the “Free” mode
0 = Timer indicates the exceeded speech time (counts up)
1 = MCS 221 is turned off
0 or 1
0
18
Warning signal in the “Request” mode before the speech time has elapsed;
0 = no warning signal
0 ... 59 sec.
45
19
After the speech time has elapsed in the “Request” mode:
0 = Timer indicates the exceeded speech time (counts up)
1 = Timer stops (activated MCS 221 is turned off and the registered MCS 221
must be activated by the chairman with the “Requ” button) 
2 = Timer starts again (activated MCS 221 is turned off and registered 
MCS 221 is turned on)
0 ... 2
2
20
Speech time is displayed in minutes (applies to “Free” and “Request” mode
(no. 20 and 21 are added)
0 ... 99 min.
2
21
Speech time is displayed in seconds (applies to “Free” and “Request” mode
(no. 20 and 21 are added)
0 ... 59 sec.
30