Figure 3 – Single Stage or Multi-Stage System (No Heat Pump)
with Two Transformers
Single
Stage 1
(SS1)
Multi-
Stage 2
(MS2)
O
Energized
Constantly
in
Cool Mode
B
Energized
Constantly
in Heat, Off,
Emergency
Mode
No
Output
Cool
Mode
2nd
Stage
Cool Mode
1st Stage
Blower/
Circulator
Fan Energized
on Call for
Cool (and
Heat if
configured
for Electric
Heat)
No Output
Heat Mode
2nd Stage
Heat
Mode
1st Stage
Optional 
24 Volt
(Com-
mon)
Fault
Indicator
(NOT
USED)
24 Volt
(Hot)
Cool
System
Y
G
W/E
C
L
RC
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
24 Volt
(Hot)
Heat
RH
120VAC
Remove Jumper Wire
between RH & RC
HOT
24VAC
NEUTRAL
CLASS II
TRANSFORMER
HEATING
COOLING
Y2
W2
Jumper
O/B
Single Stage
3-wire
Zone Valve
application
Blower/Circulator
Fan Energized
Opens
Valve
(4)
Constant
24 Volt
(Com-
mon)
24 Volt
(Hot)
Cool
System
6
Y
W
C
RC
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
24 Volt
(Hot)
Heat
(5)
RH
G
Jumper
Closes
Valve
(6)
NOTE: If continuous backlight or 
hardwired power input are desired but 
do not function in both HEAT and COOL 
modes, cut the heating transformer 24V 
wires and tape off. Connect the neutral 
circuit disconnected from the heating 
transformer to the neutral circuit of the 
cooling transformer. Disconnect the wire 
to the RH terminal and install a jumper 
between RH and RC. Depending on 
the system requirements, replace the 
cooling transformer with a 75VA class II 
transformer if needed.
Figure 4 – 3-Wire (SPDT) Heat Only Zone Valve Wiring