Page of 124
Operations Manual, HPA2, Compact Outdoor SSPA 
205486 REV F 
93 
Data 
Address 
# Bytes 
Description 
Limits and Byte Values 
System Operation Mode 
Single Amplifier = 255; Dual 1:1 = 1 (version 3.60); 
1:1 Redundant = 0 
System Hierarchical Address 
HPA 1= 0; HPA 2= 255 
3 1 
Unit Start Up State 
 (in Redundancy) 
Standby Amplifier = 0 
On Line Amplifier = 1 
Mute State 
Mute Clear (Transmit Enable) = 255 
Mute Set (Transmit Disable) = 0 
5 1 
Attenuation Level 
(dB down from maximum gain) 
[1 bit for every 0.1 dB] 
0 dB attenuation = 0 
20 dB attenuation = 200 
Module Gain Control Authority 
Serial Port Gain Control = 255 
External Analog Voltage Gain Control = 0 
Amplifier Network Address 
0 to 255 
High Temperature Alarm Threshold 
0 to 125 (in 
o
C) 
SSPA module Calibration Mode 
Temperature Compensated = 255  (normal state) 
Calibration Mode = 0 
10 
SSPA Spare Fault Status 
Ignore Spare Fault = 255 
Fault on value of window on ADC channel = 0 to 7 
Fault on External Mute = 8 
11 
SSPA Spare Fault Handling 
Minor Fault (no effect on Summary Fault) = 255 
Major Fault (Triggers Summary Fault) = 0 
Major Fault with Mute (Transmit Disabled) = 1 
12 
SSPA Auxiliary Fault Status 
Ignore Auxiliary Fault = 255 
Fault on Logic Low State = 1 
Fault on Logic High State = 0 
Startup in Low Z State = 2 
Startup in High Z State = 3 
(version 3.50 - See SierraCom Protocol for details) 
13 
SSPA Auxiliary Fault Handling 
Minor Fault (No effect on Summary) = 255 
Major Fault (Triggers Summary Fault) = 0 
Major Fault with Mute (Transmit Disabled) =1 
Minor Fault with Mute = 2 (version 3.50) 
14 
Block Up Converter Fault Status 
Ignore BUC Fault = 255 
Fault on Logic Low State = 1 
Fault on Logic High State = 0 
15 
Block Up Converter Fault Handling 
Minor Fault (no effect on Summary Fault) = 255 
Major Fault (Triggers Summary Fault) =0 
Major Fault with Mute (Transmit Disabled) = 1 
16 
Protocol Select 
Standard String Protocol = 255 
Terminal Mode = 0 
Binary Mode (compatible with CO SSPA serial 
 numbers 100,001 - 199,999) = 1 
SierraCom Protocol = 2 (version 3.50; compatible with    
SierraCom VSAT BUC and NDSat SkyWAN modem, see 
Appendix D for details) 
17 
Baud Rate Select 
9600 = 255 
38400 = 0 
19200 = 1 
4800 = 2 
2400 = 3 
18-19 
Reserved 
Reserved for Factory use. 
20 
Standby Mode 
Hot standby=255; Cold standby=0 (version 3.50) 
21 
BUC Reference 
Autoswitch = 0; External = 1; Internal = 2 (version 3.60) 
Table 10-6: System Settings Data Values 
Note: Data length must be at least two bytes to form integer with the lower byte sent first.  If odd number of bytes is received, the last byte 
will be saved as the lower byte of the integer and upper part will be zero.