Paradise 205486 REV F User Manual
Operations Manual, HPA2, Compact Outdoor SSPA
205486 REV F
95
Data
Address
# Bytes
Description
Limits and valid values
0
2
Current value of ADC channel 0
Reserved
Value Range: 0 to 1023
Conversion: N/A
Value Range: 0 to 1023
Conversion: N/A
1
2
Current value of ADC channel 1
RF Power Detector #1 Reflected
Value Range: 0 to 1023
Conversion: N/A
Value Range: 0 to 1023
Conversion: N/A
2
2
Current value of ADC channel 2
Analog Gain Adjust Voltage
Value Range: 0 to 1023
Conversion: 1 value = 2.44mV
Value Range: 0 to 1023
Conversion: 1 value = 2.44mV
3
2
Current value of ADC channel 3
RF Power Detector #1 Forward
Value Range: 0 to 1023
Conversion: N/A
Value Range: 0 to 1023
Conversion: N/A
4
2
Current value of ADC channel 4
Gate Voltage
Value Range: 0 to 1023
Conversion: 1 value = -9.4mV
Value Range: 0 to 1023
Conversion: 1 value = -9.4mV
5
2
Current value of ADC channel 5
Regulator Voltage
Value Range: 0 to 1023
Conversion: 1 value = 14.66 mV
Value Range: 0 to 1023
Conversion: 1 value = 14.66 mV
6
2
Current value of ADC channel 6
Power Supply Voltage
Value Range: 0 to 1023
Conversion: 1 value = 14.66 mV
Value Range: 0 to 1023
Conversion: 1 value = 14.66 mV
7
2
Current value of ADC channel 7
SSPA Current
Value Range: 0 to 1023
Conversion: 1 value = 97.75 mA
Value Range: 0 to 1023
Conversion: 1 value = 97.75 mA
Table 10-8: ADC (Analog-Digital Converter) Addressing
Table 10-9: System Threshold Data Values
Data
Address
# Bytes
Description
Limits and valid values
1
2
Low Current Fault Threshold
Minimum value = 0
Maximum value = 1023
2
2
Spare Fault Window
Lower Limit
Minimum value = 0
Maximum value = 1023
3 2
Spare Fault Window
Upper Limit
Minimum value = 0
Maximum value = 1023