14.1 Explanations of the formula abbreviations 
Data, main motor cooler 
 
Q
H,MAX
  Maximum heat loss dissipated via the main cooler when the motor is utilized up 
to the rated torque M
N
 and at the rated temperature T
N
H,MIN
 
Recommended minimum volume flow rate in the main cooler to achieve the rated 
torque M
N
ΔT
H
 
The temperature increase of the coolant between the inlet and return flow circuit 
of the main cooler at operating point Q
H,MAX
 and 
H,MIN
 can be estimated using 
the following formu
 
la: 
 
 
Average water density: ρ = 1000 kg/m
3
 
Average specific thermal capacity of water: c
p
 = 4.18 · 10
3
 J/(kg K) 
Temperature deviation from intake temperature: ΔT
H
 in K 
Volume flow: in m
3
/s 
 
˂7LQ.
&RROLQJPHGLXPWHPSHUDWXUHLQFUHDVHDWUHFRPPHQGHG
PLQLPXPYROXPHIORZUDWHDFFRUGLQJWRGDWDVKHHW
9LQOPLQ
 
Figure 14-2  Sample characteristic "Temperature increase of the coolant between the inlet and return 
flow circuit of the main cooler" 
 
Δp
H
 
Coolant pressure drop between the inlet and return flow circuit of the main cooler 
with volume flow 
H,MIN
The main and precision coolers for motors with integrated cooling are connected 
in parallel. The volume flow rates of the main and precision coolers are combined 
to create the total volume flow rate; the pressure drop in the main cooler Δp
H
 is 
the same as that in the precision cooler Δp
P
 