Technical data and characteristics 
 
14.1 Explanations of the formula abbreviations 
3UHVVXUHGURSDWUHFRPPHQGHGPLQLPXP
YROXPHIORZUDWHDFFRUGLQJWRGDWDVKHHW
˂SLQEDU
9LQOPLQ
 
Figure 14-3  Sample characteristic: "Pressure losses in the main cooler over volume flow rate" 
Data, precision motor cooler 
 
Q
P,MAX
  Maximum heat loss dissipated via the precision cooler when the motor is utilized 
up to the rated torque M
N
 and at the rated temperature T
N
P,MIN
 
Recommended minimum volume flow rate in the precision cooler to achieve a 
minimum temperature increase on the mounting surface of the stator vis-à-vis 
T
VORL
ΔT
p
 
The temperature increase of the coolant between the intake and return flow 
circuit of the precision cooler at operating point Q
P,MAX
 and 
P,MIN
 can be 
estimated using the following formula: 
 
 
 
Average water density: ρ = 1000 kg/m
3
 
Average specific thermal capacity of water: c
p
 = 4.18 · 10
3
 J/(kg K) 
Temperature deviation from intake temperature: ΔT
P
 in K 
Volume flow: in m
3
/s 
 
˂7LQ.
&RROLQJPHGLXPWHPSHUDWXUHLQFUHDVHDWUHFRPPHQGHG
PLQLPXPYROXPHIORZUDWHDFFRUGLQJWRGDWDVKHHW
9LQOPLQ
 
Figure 14-4  Sample characteristic "Temperature increase of the coolant between the inlet and return 
flow circuit of the precision cooler" 
 
1FW6 Built-in torque motors 
202
 
Configuration Manual, 05/2009, 6SN1197-0AD00-0BP7