Siemens TV Converter Box 611 User Manual

Page of 324
Technical data and characteristics 
 
14.2 Data sheets and diagrams 
Data sheet 1FW6090-xxB07-xxxx 
Table 14- 2  1FW6090-xxB07-0Kxx, 1FW6090-xxB07-1Jxx 
Technical data 
1FW6090 
Symbol 
Unit 
-xxB07-0Kxx  -xxB07-1Jxx   
Boundary conditions 
 
 
 
 
 
DC link voltages 
U
ZK
 
600 
600 
 
Water cooling inlet temperature 
T
VORL
 
°C 
35 
35 
 
Rated temperature of winding 
T
N
 
°C 
130 
130 
 
Rated data 
 
 
 
 
 
Rated torque 
M
N
 
Nm 
154 
142 
 
Rated current 
I
N
 
9.5 
13 
 
Maximum speed at rated torque 
n
MAX,MN
 
rpm 
220 
430 
 
Rated power dissipation 
P
V,N
 
kW 
2.69 
2.67 
 
Limit data 
 
 
 
 
 
Maximum torque 
M
MAX
 
Nm 
251 
251 
 
Maximum current 
I
MAX
 
16 
26 
 
Electric power of motor at M
MAX
 
P
EL,MAX
 
kW 
10.3 
14.1 
 
Maximum speed at maximum torque 
n
MAX,MMAX
  rpm 
120 
270 
 
No-load speed 
n
MAX,0
 
rpm 
390 
620 
 
Torque at n = 1 [rpm] 
M
0
 
Nm 
166 
166 
 
Current at M
0
 and n = 1 [rpm] 
I
0
 
10 
16 
 
Thermal static torque 
M
0
Nm 
118 
118 
 
Thermal stall current 
I
0
7.1 
11 
 
Physical constants 
 
 
 
 
 
Torque constant at 20 °C 
k
T,20
 
Nm/A 
16.6 
10.5 
 
Voltage constant 
k
E
 
V/(1000/min) 
1007 
634.3 
 
Motor constant at 20 °C 
k
M,20
 
Nm/(W)
0.5
 
3.33 
3.34 
 
Thermal time constant 
t
TH
 
60 
60 
 
No. of pole pairs 
22 
22 
 
Cogging torque 
M
COG
 
Nm 
1.7 
1.7 
 
Stator mass 
m
S
 
kg 
8.6 
8.6 
 
Rotor mass 
m
L
 
kg 
3.6 
3.6 
 
Rotor moment of inertia 
J
L
 
10
-2
 kgm
2
 
2.2 
2.2 
 
Phase resistance of winding at 20 °C 
R
STR, 20
 
Ω 
5.98 
2.36 
 
Phase inductance of winding 
L
STR
 
mH 
21.2 
8.4 
 
Data, main motor cooler 
 
 
 
 
 
Maximum dissipated thermal power 
Q
H,MAX
 
kW 
2.24 
2.22 
 
Recommended minimum volume flow rate 
H,MIN
 
l/min 
4.1 
4.1 
 
Temperature increase of the coolant 
ΔT
H
 
7.8 
7.8 
 
Pressure drop 
Δp
H
 
bar 
0.2 
0.2 
 
 
1FW6 Built-in torque motors 
206
 
Configuration Manual, 05/2009, 6SN1197-0AD00-0BP7