Siemens TV Converter Box 611 User Manual

Page of 324
Technical data and characteristics 
 
14.2 Data sheets and diagrams 
14.2 
Data sheets and diagrams 
14.2.1 
1FW6090-xxxxx-xxxx 
Data sheet 1FW6090-xxB05-xxxx 
Table 14- 1  1FW6090-xxB05-0Fxx, 1FW6090-xxB05-0Kxx  
Technical data 
1FW6090 
Symbol 
Unit 
-xxB05-0Fxx  -xxB05-0Kxx   
Boundary conditions 
 
 
 
 
 
DC link voltages 
U
ZK
 
600 
600 
 
Water cooling intake temperature 
T
VORL
 
°C 
35 
35 
 
Rated temperature of winding 
T
N
 
°C 
130 
130 
 
Rated data 
 
 
 
 
 
Rated torque 
M
N
 
Nm 
113 
109 
 
Rated current 
I
N
 
5.6 
7.4 
 
Maximum speed at rated torque 
n
MAX,MN
 
rpm 
140 
250 
 
Rated power loss 
P
V,N
 
kW 
2.19 
2.12 
 
Limit data 
 
 
 
 
 
Maximum torque 
M
MAX
 
Nm 
179 
179 
 
Maximum current 
I
MAX
 
9.5 
13 
 
Electric power of motor at M
MAX
 
P
EL,MAX
 
kW 
6.55 
8.12 
 
Maximum speed at maximum torque 
n
MAX,MMAX
  rpm 
46 
140 
 
No-load speed 
n
MAX,0
 
rpm 
310 
430 
 
Torque at n = 1 [rpm] 
M
0
 
Nm 
119 
119 
 
Current at M
0
 and n = 1 [rpm] 
I
0
 
5.9 
8.2 
 
Thermal static torque 
M
0
Nm 
84.1 
84.1 
 
Thermal stall current 
I
0
4.1 
5.6 
 
Physical constants 
 
 
 
 
 
Torque constant at 20 °C 
k
T,20
 
Nm/A 
20.8 
15 
 
Voltage constant 
k
E
 
V/(1000/min) 
1258 
906.2 
 
Motor constant at 20 °C 
k
M,20
 
Nm/(W)
0.5
 
2.64 
2.68 
 
Thermal time constant 
t
TH
 
60 
60 
 
No. of pole pairs 
22 
22 
 
Cogging torque 
M
COG
 
Nm 
1.2 
1.2 
 
Stator mass 
m
S
 
kg 
6.6 
6.6 
 
Rotor mass 
m
L
 
kg 
2.6 
2.6 
 
Rotor moment of inertia 
J
L
 
10
-2
 kgm
2
 
1.52 
1.52 
 
Phase resistance of winding at 20 °C 
R
STR, 20
 
Ω 
14.9 
7.5 
 
Phase inductance of winding 
L
STR
 
mH 
47.1 
24.4 
 
 
1FW6 Built-in torque motors 
204
 
Configuration Manual, 05/2009, 6SN1197-0AD00-0BP7