Siemens TV Converter Box 611 User Manual
Technical data and characteristics
14.2 Data sheets and diagrams
Data sheet 1FW6090-xxB15-xxxx
Table 14- 4 1FW6090-xxB15-1Jxx, 1FW6090-xxB15-2Jxx
Technical data
1FW6090
1FW6090
Symbol
Unit
-xxB15-1Jxx -xxB15-2Jxx
Boundary conditions
DC link voltages
U
ZK
V
600
600
Water cooling inlet temperature
T
VORL
°C
35
35
Rated temperature of winding
T
N
°C
130
130
Rated data
Rated torque
M
N
Nm
338
319
Rated current
I
N
A
15
23
Maximum speed at rated torque
n
MAX,MN
rpm
150
310
Rated power dissipation
P
V,N
kW
4.87
4.96
Limit data
Maximum torque
M
MAX
Nm
537
537
Maximum current
I
MAX
A
26
43
Electric power of motor at M
MAX
P
EL,MAX
kW
17.1
24.1
Maximum speed at maximum torque
n
MAX,MMAX
rpm
78
200
No-load speed
n
MAX,0
rpm
290
470
Torque at n = 1 [rpm]
M
0
Nm
357
357
Current at M
0
and n = 1 [rpm]
I
0
A
16
26
Thermal static torque
M
0
*
Nm
252
252
Thermal stall current
I
0
*
A
11
18
Physical constants
Torque constant at 20 °C
k
T,20
Nm/A
22.5
13.7
Voltage constant
k
E
V/(1000/min)
1359
831.3
Motor constant at 20 °C
k
M,20
Nm/(W)
0.5
5.3
5.25
Thermal time constant
t
TH
s
60
60
No. of pole pairs
p
-
22
22
Cogging torque
M
COG
Nm
3.6
3.6
Stator mass
m
S
kg
19.5
19.5
Rotor mass
m
L
kg
7.7
7.7
Rotor moment of inertia
J
L
10
-2
kgm
2
4.65
4.65
Phase resistance of winding at 20 °C
R
STR, 20
Ω
4.3
1.64
Phase inductance of winding
L
STR
mH
17.7
6.6
Data, main motor cooler
Maximum dissipated thermal power
Q
H,MAX
kW
4.05
4.13
Recommended minimum volume flow rate
H,MIN
l/min
7
7
Temperature increase of the coolant
ΔT
H
K
8.3
8.5
Pressure drop
Δp
H
bar
0.6
0.6
1FW6 Built-in torque motors
210
Configuration Manual, 05/2009, 6SN1197-0AD00-0BP7