Siemens TV Converter Box 611 User Manual

Page of 324
Technical data and characteristics 
 
14.2 Data sheets and diagrams 
14.2.2 
1FW6130-xxxxx-xxxx 
Data sheet 1FW6130-xxB05-xxxx 
Table 14- 5  1FW6130-xxB05-0Kxx, 1FW6130-xxB05-1Jxx  
Technical data 
1FW6130 
Symbol 
Unit 
-xxB05-0Kxx  -xxB05-1Jxx   
Boundary conditions 
 
 
 
 
 
DC link voltages 
U
ZK
 
600 
600 
 
Water cooling inlet temperature 
T
VORL
 
°C 
35 
35 
 
Rated temperature of winding 
T
N
 
°C 
130 
130 
 
Rated data 
 
 
 
 
 
Rated torque 
M
N
 
Nm 
241 
217 
 
Rated current 
I
N
 
14 
 
Maximum speed at rated torque 
n
MAX,MN
 
rpm 
130 
310 
 
Rated power dissipation 
P
V,N
 
kW 
2.93 
2.93 
 
Limit data 
 
 
 
 
 
Maximum torque 
M
MAX
 
Nm 
439 
439 
 
Maximum current 
I
MAX
 
18 
32 
 
Electric power of motor at M
MAX
 
P
EL,MAX
 
kW 
12.2 
18.3 
 
Maximum speed at maximum torque 
n
MAX,MMAX
  rpm 
47 
180 
 
No-load speed 
n
MAX,0
 
rpm 
240 
420 
 
Torque at n = 1 [rpm] 
M
0
 
Nm 
258 
258 
 
Current at M
0
 and n = 1 [rpm] 
I
0
 
9.7 
17 
 
Thermal static torque 
M
0
Nm 
183 
183 
 
Thermal stall current 
I
0
6.7 
12 
 
Physical constants 
 
 
 
 
 
Torque constant at 20 °C 
k
T,20
 
Nm/A 
27.3 
15.3 
 
Voltage constant 
k
E
 
V/(1000/min) 
1650 
924.9 
 
Motor constant at 20 °C 
k
M,20
 
Nm/(W)
0.5
 
4.93 
4.92 
 
Thermal time constant 
t
TH
 
60 
60 
 
No. of pole pairs 
33 
33 
 
Cogging torque 
M
COG
 
Nm 
1.3 
1.3 
 
Stator mass 
m
S
 
kg 
8.7 
8.7 
 
Rotor mass 
m
L
 
kg 
4.5 
4.5 
 
Rotor moment of inertia 
J
L
 
10
-2
 kgm
2
 
6.37 
6.37 
 
Phase resistance of winding at 20 °C 
R
STR, 20
 
Ω 
7.34 
2.31 
 
Phase inductance of winding 
L
STR
 
mH 
19.2 
 
Data, main motor cooler 
 
 
 
 
 
Maximum dissipated thermal power 
Q
H,MAX
 
kW 
2.43 
2.44 
 
Recommended minimum volume flow rate 
H,MIN
 
l/min 
4.1 
4.1 
 
 
1FW6 Built-in torque motors 
212
 