Configuring the motor 
 
5.1 Procedure 
5.1.5 
Uneven current load 
If the load is uneven over a long period of time, the motor must only be operated at no more 
than 70% of the rated torque (see also M
0
* in "Technical data"). 
For exact configurations, contact your local Siemens office. 
 
NOTICE 
 
Not all of the three phases are necessarily evenly loaded in all motor operating modes. 
Examples of uneven current load: 
 
Standstill with current feed of the motor, e.g. for: 
–  Compensation of a weight force 
–  Start-up against a brake system (damping and impact absorption elements) 
 
Low speeds over a long period (n << 1 [rpm]) 
 
Cyclic rotation (path on rotor circumference < pole width) 
 
 
5.1.6 
Motor torque-speed diagram 
Checking the torques and speeds 
At high speeds, the maximum available motor torque is limited by the available DC link 
voltage. If the speeds that occur in the motional sequence are greater than the maximum 
speed n
MAX,MMAX
 specified for the motor type at the maximum torque M
MAX
, you may have to 
check the torques and speeds using the motor torque-speed diagram. This diagram is 
included with the motor specifications. 
 
Figure 5-4 
Motor torque-speed diagram 
1FW6 Built-in torque motors 
Configuration Manual, 05/2009, 6SN1197-0AD00-0BP7 
69