Sharp Digital Signage Software Viewer PNSV01 User Manual

Page of 117
102
FTP Server/Client Scheduler
•  [Test connection]
 Check the connection to confirm that the panel can be controlled. After the connection is established
successfully, the model name of the panel is acquired and displayed. Perform operation with the power
of the panel turned on. To control the panel with the LB-1085, be sure to check the connection once. The
panel cannot be controlled unless a “Test connection” is performed.
•  “Multiple Panels” option button
 You can select and control panels from up to 25 panels. You can also set power control, entry method,
timing, and PIP functions. In addition, you can acquire the status of each panel and other information.
•  [Connection Setting]
  A list of connected panels appears when you click 
[Connection Setting].
 Add panels to the list the first time you use this function
by clicking [Add].
Setting
Description
Default
RS-232C
COM port
COM1~COM256
COM1
Baud Rate
9600, 19200, 38400
9600
LAN
Host name or IP 
address
Enter the host name or the IP address of the panel to be
controlled within 32 alphanumeric characters.
-
Data port
Enter a data port number between 1025 and 65535 for the
panels to be controlled.
10008
User name
Enter the username, if one exists for the panels to be
controlled, in 8 characters or less.
-
Password
Enter the password, if one exists for the panels to be
controlled, in 8 characters or less.
-
Panel IDs
Select IDs in order to identify panels when PCs are connected
in a daisy chain.
(Do not connect in a daisy chain), 1-255
(Do not 
connect in a 
daisy chain)
•  “Power ON the panel before starting up this software.” check box
 When this check box is checked, the power of the panel is turned on when the Client Scheduler is
started.
 * The function of turning on the power of the panel cannot be used with the LB-46GX35 and
LB-52GX35.
•  “Power OFF the panel before exiting this software.” check box
 When this check box is checked, the power of the panel is turned off when the Client Scheduler is
terminated.
•  “Synchronize the panel time with PC time before starting up this software.” check box
 When this check box is checked, the clock of the panel is set to the time of the target PC when the Client
Scheduler is launched. 
Client Scheduler