HP 160 G6 490455-421 User Manual

Product codes
490455-421
Page of 55
HP 750W Common Slot Gold Hot Plug Factory Integrated Power Supply Kit with Backplane
Part Number
535683-B21 Option Kit
Input Voltage Range (Vrms)
100 to 240
Frequency Range (Nominal) (Hz)
50/60
Nominal Input Voltage (Vrms)
100
120
200
208
220
230
240
Maximum Rated Output Wattage
Rating
750
750
750
750
750
750
750
Nominal Input Current (A rms)
8.9
7.4
4.3
4.1
3.9
3.7
3.6
Maximum Rated Input Wattage
Rating (Watts)
857
847
824
825
820
820
820
Maximum Rated VA (Volt-Amp)
894
884
859
859
854
854
854
Efficiency (%)
87.5
88.5
91
91
91.5
91.5
91.5
Power Factor
0.97
Leakage Current (mA)
0.42
0.50
0.83
0.87
0.92
0.96
1.00
Maximum Inrush Current (A peak)
30
Maximum Inrush Current duration
(mS)
20
Maximum British Thermal Unit
Rating (BTU-Hr)
2925
2892
2812
2812
2797
2797
2797
 
HP 500W Factory Integrated Power Supply Kit
Part Number
515915-B21 Option Kit
Input Voltage Range (Vrms)
100 to 240
Frequency Range (Nominal) (Hz)
47/63
Nominal Input Voltage (Vrms)
100
120
200
220
230
240
Maximum Rated Output Wattage
500
500
500
500
500
500
Nominal Input Current (A rms)
5.74
4.99
2.86
2.58
2.46
2.36
Maximum Rated Input Wattage
Rating (Watts)
568
568
562
556
556
556
Maximum Rated VA (Volt-Amp)
574
574
573
567
567
567
Efficiency (%)
88
88
89
90
90
90
Power Factor
0.99
0.99
0.98
0.98
0.98
0.98
Leakage Current (mA)
0.42
0.50
0.81
0.91
0.95
1.00
Maximum Inrush Current (A peak)
30
Maximum Inrush Current duration
(mS)
20
Maximum British Thermal Unit
Rating (BTU-Hr)
 
 
 
 
 
 
 
QuickSpecs
HP ProLiant DL160 Generation 6 (G6)
Power Specifications
DA - 13247   Worldwide — Version 59 — September 24, 2012