HP 160 G6 490455-421 User Manual

Product codes
490455-421
Page of 55
HP 460W Common Slot Gold Hot Plug Factory Integrated Power Supply Kit with Backplane
Part Number
535684-B21 Option Kit
Input Voltage Range (Vrms)
100 to 240
Frequency Range (Nominal) (Hz)
50/60
Nominal Input Voltage (Vrms)
100
120
200
208
220
230
240
Maximum Rated Output Wattage
460
460
460
460
460
460
460
Nominal Input Current (A rms)
5.5
4.5
2.6
2.5
2.4
2.3
2.2
Maximum Rated Input Wattage
Rating (Watts)
526
520
505
505
503
503
503
Maximum Rated VA (Volt-Amp)
548
542
527
527
524
524
524
Efficiency (%)
87.5
88.5
91
91
91.5
91.5
91.5
Power Factor
0.97
Leakage Current (mA)
0.42
0.50
0.83
0.87
0.92
0.96
1.00
Maximum Inrush Current (A peak)
30
Maximum Inrush Current duration
(mS)
20
Maximum British Thermal Unit
Rating (BTU-Hr)
1794
1773
1725
1725
1715
1715
1715
 
HP 365W Hot Plug Redundant Power Supply Kit with Backplane
Part Number
532092-B21 Option Kit
Input Voltage Range (Vrms)
100 to 240
Frequency Range (Nominal) (Hz)
50/60
Nominal Input Voltage (Vrms)
100
120
200
208
220
230
240
Maximum Rated Output Wattage
320
320
360
360
360
360
360
Nominal Input Current (A rms)
4.15
3.41
2.23
2.16
2.03
1.94
1.86
Maximum Rated Input Wattage
Rating (Watts)
412
406
445
445
444
443
443
Maximum Rated VA (Volt-Amp)
413
407
447
447
446
446
445
Efficiency (%)
77.4
78.5
80.5
80.6
80.7
80.8
81.0
Power Factor
0.99
Leakage Current (mA)
0.75
0.75
0.85
0.90
0.95
0.95
1.00
Maximum Inrush Current (A peak)
35
Maximum Inrush Current duration
(mS)
20
Maximum British Thermal Unit
Rating (BTU-Hr)
1354
1334
1462
1462
1459
1456
1456
 
QuickSpecs
HP ProLiant DL160 Generation 6 (G6)
Power Specifications
DA - 13247   Worldwide — Version 59 — September 24, 2012
Page  49